Mid-Term Outcomes of Transcatheter Aortic Valve Replacement in Extremely Large Annuli With Edwards SAPIEN 3 Valve

The aim of this study was to report the 1-year results of transcatheter aortic valve replacement (TAVR) with the Edwards SAPIEN 3 (S3) valve in extremely large annuli. Favorable 30-day outcomes of S3 TAVR in annuli >683 mm2 have previously been reported. Pacemaker implantation rates were acceptab...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:JACC. Cardiovascular interventions 2020-01, Vol.13 (2), p.210-216
Hauptverfasser: Sengupta, Aditya, Zaid, Syed, Kamioka, Norihiko, Terre, Juan, Miyasaka, Masaki, Hirji, Sameer A., Hensey, Mark, Geloo, Nadim, Petrossian, George, Robinson, Newell, Sarin, Eric, Ryan, Liam, Yoon, Sung-Han, Tan, Christina W., Khalique, Omar K., Kodali, Susheel K., Kaneko, Tsuyoshi, Shah, Pinak B., Wong, S. Chiu, Salemi, Arash, Sharma, Kapil, Kozina, Joseph A., Szerlip, Molly A., Don, Creighton W., Gafoor, Sameer, Zhang, Ming, Newhart, Zachary, Kapadia, Samir R., Mick, Stephanie L., Krishnaswamy, Amar, Kini, Annapoorna, Ahmad, Hasan, Lansman, Steven L., Mack, Michael J., Webb, John G., Babaliaros, Vasilis, Thourani, Vinod H., Makkar, Raj R., Leon, Martin B., George, Isaac, Tang, Gilbert H.L.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The aim of this study was to report the 1-year results of transcatheter aortic valve replacement (TAVR) with the Edwards SAPIEN 3 (S3) valve in extremely large annuli. Favorable 30-day outcomes of S3 TAVR in annuli >683 mm2 have previously been reported. Pacemaker implantation rates were acceptable, and a larger left ventricular outflow tract and more eccentric annular anatomy were associated with increasing paravalvular leak. From December 2013 to December 2018, 105 patients across 15 centers with mean area 721.3 ± 36.1 mm2 (range 683.5 to 852.0 mm2) underwent TAVR using an S3 device. Clinical, anatomic, and procedural characteristics were analyzed. One-year survival and echocardiographic follow-up were reached in 94.3% and 82.1% of patients, respectively. Valve Academic Research Consortium-2 30-day and 1-year outcomes were reported. The mean age was 76.9 ± 10.4 years, and Society of Thoracic Surgeons predicted risk score averaged 5.2 ± 3.4%. One-year overall mortality and stroke rates were 18.2% and 2.4%, respectively. Quality-of-life index improved from baseline to 30 days and at 1 year (p 683 mm2 is feasible, with favorable mid-term outcomes. [Display omitted]
ISSN:1936-8798
1876-7605
DOI:10.1016/j.jcin.2019.08.042