A further development of the fluorescent gated gas scintillation proportional counter
Recent results from a K gated gas scintillation proportional counter filled with a xenon/helium mixture to a pressure of about 3 bar have already shown that a background rejection efficiency in excess of 99.3% can be achieved in the energy range 35-100 keV. In addition the application of the techniq...
Gespeichert in:
Veröffentlicht in: | IEEE Trans. Nucl. Sci.; (United States) 1983-02, Vol.NS-30, p.394-397 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 397 |
---|---|
container_issue | |
container_start_page | 394 |
container_title | IEEE Trans. Nucl. Sci.; (United States) |
container_volume | NS-30 |
creator | Sims, M R Peacock, A Taylor, B G |
description | Recent results from a K gated gas scintillation proportional counter filled with a xenon/helium mixture to a pressure of about 3 bar have already shown that a background rejection efficiency in excess of 99.3% can be achieved in the energy range 35-100 keV. In addition the application of the technique of fluorescent gating also provides energy resolutions below 3% at about 60 keV. Experimental results are presented for a gas scintillation counter filled with a krypton/xenon mixture which, through the use of the krypton K fluorescent gate, enables a high background rejection and improved energy resolution, for the energy range above 14 keV, to be achieved. |
doi_str_mv | 10.1109/TNS.1983.4332297 |
format | Article |
fullrecord | <record><control><sourceid>proquest_osti_</sourceid><recordid>TN_cdi_proquest_miscellaneous_23193636</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>23193636</sourcerecordid><originalsourceid>FETCH-LOGICAL-o211t-d68b103a1e7b98fa6a3dbfef0a6844b79be251d2ab7412b57b71ebc12afa39573</originalsourceid><addsrcrecordid>eNotjz1PwzAQhj2ARCnsjBYDW0LOjuN4rCq-pAoG2jmynTMNSu0SO_x-XJU76T5evTo9R8gdVCVApR63758lqJaXNeeMKXlBFlUFbaFqpa7IdYzfea1FJRZkt6JuntIeJ9rjL47heECfaHA0a9SNc5gw2pP0pRP2uUYa7eDTMI46DcHT4xSOYTqNeqQ2zD7hdEMunR4j3v73Jdk9P23Xr8Xm4-VtvdoUgQGkom9aAxXXgNKo1ulG8944dJVu2ro2UhlkAnqmjayBGSGNBDQWmHaaKyH5ktyf74aYhi5zJbR7G7xHmzrRCpYjmx7Opkz6M2NM3WHIL2V-j2GOHeOgeJPzD546YGE</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>23193636</pqid></control><display><type>article</type><title>A further development of the fluorescent gated gas scintillation proportional counter</title><source>IEEE Electronic Library (IEL)</source><creator>Sims, M R ; Peacock, A ; Taylor, B G</creator><creatorcontrib>Sims, M R ; Peacock, A ; Taylor, B G ; Space Science Department of the European Space Agency, European Space Research and Technology Centre, Noordwijk</creatorcontrib><description>Recent results from a K gated gas scintillation proportional counter filled with a xenon/helium mixture to a pressure of about 3 bar have already shown that a background rejection efficiency in excess of 99.3% can be achieved in the energy range 35-100 keV. In addition the application of the technique of fluorescent gating also provides energy resolutions below 3% at about 60 keV. Experimental results are presented for a gas scintillation counter filled with a krypton/xenon mixture which, through the use of the krypton K fluorescent gate, enables a high background rejection and improved energy resolution, for the energy range above 14 keV, to be achieved.</description><identifier>ISSN: 0018-9499</identifier><identifier>DOI: 10.1109/TNS.1983.4332297</identifier><language>eng</language><publisher>United States</publisher><subject>440101 - Radiation Instrumentation- General Detectors or Monitors & Radiometric Instruments ; DATA ; EFFICIENCY ; ELEMENTS ; ENERGY RANGE ; ENERGY RESOLUTION ; EXPERIMENTAL DATA ; FLUIDS ; FLUORESCENCE ; GAS SCINTILLATION DETECTORS ; GASES ; HELIUM ; INFORMATION ; INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY ; KEV RANGE ; KEV RANGE 10-100 ; KRYPTON ; LUMINESCENCE ; MEASURING INSTRUMENTS ; NONMETALS ; NUMERICAL DATA ; PROPORTIONAL COUNTERS ; RADIATION DETECTORS ; RARE GASES ; RESOLUTION ; SCINTILLATION COUNTERS ; XENON</subject><ispartof>IEEE Trans. Nucl. Sci.; (United States), 1983-02, Vol.NS-30, p.394-397</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,782,786,887,27931,27932</link.rule.ids><backlink>$$Uhttps://www.osti.gov/biblio/5852222$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Sims, M R</creatorcontrib><creatorcontrib>Peacock, A</creatorcontrib><creatorcontrib>Taylor, B G</creatorcontrib><creatorcontrib>Space Science Department of the European Space Agency, European Space Research and Technology Centre, Noordwijk</creatorcontrib><title>A further development of the fluorescent gated gas scintillation proportional counter</title><title>IEEE Trans. Nucl. Sci.; (United States)</title><description>Recent results from a K gated gas scintillation proportional counter filled with a xenon/helium mixture to a pressure of about 3 bar have already shown that a background rejection efficiency in excess of 99.3% can be achieved in the energy range 35-100 keV. In addition the application of the technique of fluorescent gating also provides energy resolutions below 3% at about 60 keV. Experimental results are presented for a gas scintillation counter filled with a krypton/xenon mixture which, through the use of the krypton K fluorescent gate, enables a high background rejection and improved energy resolution, for the energy range above 14 keV, to be achieved.</description><subject>440101 - Radiation Instrumentation- General Detectors or Monitors & Radiometric Instruments</subject><subject>DATA</subject><subject>EFFICIENCY</subject><subject>ELEMENTS</subject><subject>ENERGY RANGE</subject><subject>ENERGY RESOLUTION</subject><subject>EXPERIMENTAL DATA</subject><subject>FLUIDS</subject><subject>FLUORESCENCE</subject><subject>GAS SCINTILLATION DETECTORS</subject><subject>GASES</subject><subject>HELIUM</subject><subject>INFORMATION</subject><subject>INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY</subject><subject>KEV RANGE</subject><subject>KEV RANGE 10-100</subject><subject>KRYPTON</subject><subject>LUMINESCENCE</subject><subject>MEASURING INSTRUMENTS</subject><subject>NONMETALS</subject><subject>NUMERICAL DATA</subject><subject>PROPORTIONAL COUNTERS</subject><subject>RADIATION DETECTORS</subject><subject>RARE GASES</subject><subject>RESOLUTION</subject><subject>SCINTILLATION COUNTERS</subject><subject>XENON</subject><issn>0018-9499</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1983</creationdate><recordtype>article</recordtype><recordid>eNotjz1PwzAQhj2ARCnsjBYDW0LOjuN4rCq-pAoG2jmynTMNSu0SO_x-XJU76T5evTo9R8gdVCVApR63758lqJaXNeeMKXlBFlUFbaFqpa7IdYzfea1FJRZkt6JuntIeJ9rjL47heECfaHA0a9SNc5gw2pP0pRP2uUYa7eDTMI46DcHT4xSOYTqNeqQ2zD7hdEMunR4j3v73Jdk9P23Xr8Xm4-VtvdoUgQGkom9aAxXXgNKo1ulG8944dJVu2ro2UhlkAnqmjayBGSGNBDQWmHaaKyH5ktyf74aYhi5zJbR7G7xHmzrRCpYjmx7Opkz6M2NM3WHIL2V-j2GOHeOgeJPzD546YGE</recordid><startdate>19830201</startdate><enddate>19830201</enddate><creator>Sims, M R</creator><creator>Peacock, A</creator><creator>Taylor, B G</creator><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope><scope>OTOTI</scope></search><sort><creationdate>19830201</creationdate><title>A further development of the fluorescent gated gas scintillation proportional counter</title><author>Sims, M R ; Peacock, A ; Taylor, B G</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-o211t-d68b103a1e7b98fa6a3dbfef0a6844b79be251d2ab7412b57b71ebc12afa39573</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1983</creationdate><topic>440101 - Radiation Instrumentation- General Detectors or Monitors & Radiometric Instruments</topic><topic>DATA</topic><topic>EFFICIENCY</topic><topic>ELEMENTS</topic><topic>ENERGY RANGE</topic><topic>ENERGY RESOLUTION</topic><topic>EXPERIMENTAL DATA</topic><topic>FLUIDS</topic><topic>FLUORESCENCE</topic><topic>GAS SCINTILLATION DETECTORS</topic><topic>GASES</topic><topic>HELIUM</topic><topic>INFORMATION</topic><topic>INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY</topic><topic>KEV RANGE</topic><topic>KEV RANGE 10-100</topic><topic>KRYPTON</topic><topic>LUMINESCENCE</topic><topic>MEASURING INSTRUMENTS</topic><topic>NONMETALS</topic><topic>NUMERICAL DATA</topic><topic>PROPORTIONAL COUNTERS</topic><topic>RADIATION DETECTORS</topic><topic>RARE GASES</topic><topic>RESOLUTION</topic><topic>SCINTILLATION COUNTERS</topic><topic>XENON</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sims, M R</creatorcontrib><creatorcontrib>Peacock, A</creatorcontrib><creatorcontrib>Taylor, B G</creatorcontrib><creatorcontrib>Space Science Department of the European Space Agency, European Space Research and Technology Centre, Noordwijk</creatorcontrib><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>OSTI.GOV</collection><jtitle>IEEE Trans. Nucl. Sci.; (United States)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sims, M R</au><au>Peacock, A</au><au>Taylor, B G</au><aucorp>Space Science Department of the European Space Agency, European Space Research and Technology Centre, Noordwijk</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A further development of the fluorescent gated gas scintillation proportional counter</atitle><jtitle>IEEE Trans. Nucl. Sci.; (United States)</jtitle><date>1983-02-01</date><risdate>1983</risdate><volume>NS-30</volume><spage>394</spage><epage>397</epage><pages>394-397</pages><issn>0018-9499</issn><abstract>Recent results from a K gated gas scintillation proportional counter filled with a xenon/helium mixture to a pressure of about 3 bar have already shown that a background rejection efficiency in excess of 99.3% can be achieved in the energy range 35-100 keV. In addition the application of the technique of fluorescent gating also provides energy resolutions below 3% at about 60 keV. Experimental results are presented for a gas scintillation counter filled with a krypton/xenon mixture which, through the use of the krypton K fluorescent gate, enables a high background rejection and improved energy resolution, for the energy range above 14 keV, to be achieved.</abstract><cop>United States</cop><doi>10.1109/TNS.1983.4332297</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0018-9499 |
ispartof | IEEE Trans. Nucl. Sci.; (United States), 1983-02, Vol.NS-30, p.394-397 |
issn | 0018-9499 |
language | eng |
recordid | cdi_proquest_miscellaneous_23193636 |
source | IEEE Electronic Library (IEL) |
subjects | 440101 - Radiation Instrumentation- General Detectors or Monitors & Radiometric Instruments DATA EFFICIENCY ELEMENTS ENERGY RANGE ENERGY RESOLUTION EXPERIMENTAL DATA FLUIDS FLUORESCENCE GAS SCINTILLATION DETECTORS GASES HELIUM INFORMATION INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY KEV RANGE KEV RANGE 10-100 KRYPTON LUMINESCENCE MEASURING INSTRUMENTS NONMETALS NUMERICAL DATA PROPORTIONAL COUNTERS RADIATION DETECTORS RARE GASES RESOLUTION SCINTILLATION COUNTERS XENON |
title | A further development of the fluorescent gated gas scintillation proportional counter |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-03T21%3A12%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_osti_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20further%20development%20of%20the%20fluorescent%20gated%20gas%20scintillation%20proportional%20counter&rft.jtitle=IEEE%20Trans.%20Nucl.%20Sci.;%20(United%20States)&rft.au=Sims,%20M%20R&rft.aucorp=Space%20Science%20Department%20of%20the%20European%20Space%20Agency,%20European%20Space%20Research%20and%20Technology%20Centre,%20Noordwijk&rft.date=1983-02-01&rft.volume=NS-30&rft.spage=394&rft.epage=397&rft.pages=394-397&rft.issn=0018-9499&rft_id=info:doi/10.1109/TNS.1983.4332297&rft_dat=%3Cproquest_osti_%3E23193636%3C/proquest_osti_%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=23193636&rft_id=info:pmid/&rfr_iscdi=true |