Scanning electron microscope analysis of fretting fatigue damage
Scanning electron microscope examinations of surfaces damaged by fretting fatigue were performed to establish variations in microstructural and environmental effects on the fretting fatigue process of ferrite/pearlite and martensite microstructures of a .40 .50 carbon steel. The observations suggest...
Gespeichert in:
Veröffentlicht in: | Wear 1978-01, Vol.48 (1), p.87-92 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Scanning electron microscope examinations of surfaces damaged by fretting fatigue were performed to establish variations in microstructural and environmental effects on the fretting fatigue process of ferrite/pearlite and martensite microstructures of a
.40
.50
carbon steel. The observations suggest differences in fretting mechanisms in laboratory air and “vacuum” conditions as well as differences due to surface hardness. |
---|---|
ISSN: | 0043-1648 1873-2577 |