Aim Aortic stenosis is a frequent valvular disease, with transcatheter aortic valve implantation (TAVI) being performed when surgical replacement is at increased risk. However, TAVI-induced effects on myocardial efficiency are unknown. We aimed to investigate changes in LV mechano-energetic pre-/pos...
Gespeichert in:
Veröffentlicht in: | Clinical research in cardiology 2020-07, Vol.109 (7), p.819-831 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Aim
Aortic stenosis is a frequent valvular disease, with transcatheter aortic valve implantation (TAVI) being performed when surgical replacement is at increased risk. However, TAVI-induced effects on myocardial efficiency are unknown. We aimed to investigate changes in LV mechano-energetic pre-/post-TAVI and their prognostic impact.
Methods
A total of 46 patients (25 males) received transesophageal and simultaneous radial pressure plus transaortic gradient monitoring before/immediately after prosthesis deployment. Efficiency was computed as external work/potential energy, as derived from LV pressure–volume plots; myocardial oxygen consumption (MVO
2
) was estimated as PWI
mod
, i.e. a noninvasively validated alternative for MVO
2
estimation.
Results
TAVI was successful in all patients, peak transaortic gradient decreasing − 40 ± 20 mmHg (
p
< 0.001). Efficiency improved post-TAVI (+ 0.6 ± 0.12;
p
= 0.004), with a concomitant PWI
mod
reduction (− 16 ± 31%;
p
< 0.001). When contextualized to fixed PWI
mod
value (5 ml/min/100 g), efficiency significantly affected survival (
p
= 0.029). Over 1026 ± 450-day follow-up, a change in efficiency pre-/post-TAVI ≤ 0.021 (median of the difference) predicted more deaths from any cause (30%) as compared with a change > 0.021 (17%), particularly in those patients with a pre-TAVI mean high-gradient (HG ≥ 40 mmHg) phenotype (
p
< 0.05). In particular, HG patients exhibited the lowest efficiency/PWI
mod
ratio pre-/post-TAVI (
p
= 0.048), relative to the other aortic stenosis patients, suggestive of an unfavourable matching between cardiac function and metabolic demand, which foreshortens some intrinsic damaged muscle condition in these patients.
Conclusion
LV mechanical efficiency improves immediately post-TAVI, notwithstanding an inhomogeneous mechano-energetic matching among the aortic stenosis patients, which can impact negatively on their long-term prognosis, particularly in those with the HG phenotype.