Shear bond strength vs interfacial fracture toughness — Adherence to CAD/CAM blocks
•Cohesive fracture in the substratum and subsurface damage in 320 grit and 60 grit shear bond strength test samples rendered the results invalid.•Adhesive failure at the resin composite block surface occurred in all interfacial fracture toughness tests.•Fracture mechanics methodology seems to be mor...
Gespeichert in:
Veröffentlicht in: | Dental materials 2019-12, Vol.35 (12), p.1769-1775 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | •Cohesive fracture in the substratum and subsurface damage in 320 grit and 60 grit shear bond strength test samples rendered the results invalid.•Adhesive failure at the resin composite block surface occurred in all interfacial fracture toughness tests.•Fracture mechanics methodology seems to be more appropriate in testing adherence than shear bond strength test.•Thermocycling significantly reduced all results.•Adherence to CAD/CAM resin composite block may be limited by the strength of the RCB-adhesive interface.
To compare shear bond strength (SBS) and interfacial fracture toughness (IKIC) results when assessing the effect of surface roughness and thermocycling on the adherence of a resin composite luting agent (RCLA) to a CAD/CAM resin composite block (RCB).
Tetric CAD HT along with the recommended bonding system, Adhese Universal and Variolink Esthetic LC, were used. Surface roughness was achieved with 600/320/60 grit SiC papers. Samples were stored 24h in 37°C water or thermocycled 10000× (5°C–55°C) prior to testing. Results were analyzed by univariate ANOVA and Scheffé modified t-tests (α=0.05). Fractured specimens were viewed with a stereo microscope and selected specimens with a scanning electron microscope.
SBS results showed a significant difference between the 60 grit group and the other groups, both after 24h and thermocycling. A large number of SBS samples showed cohesive fracture or subsurface damage in RCB. Thermocycling led to a significant decrease in SBS in all groups. IKIC results showed no significant differences due to surface preparation after 24h storage in 37°C. After thermocycling, there was a significant difference between the 60 and the 600 grit groups. All KIC samples fractured adhesively at the RCB surface. KIC of the RCLA was significantly higher than IKIC of all groups.
The results endorse the use of fracture mechanics methodology for the assessment and characterization of adherence, while identifying difficulties in its implementation. The results suggest also that adherence to CAD/CAM RCB may be limited by the strength of the resin composite block — adhesive interface. |
---|---|
ISSN: | 0109-5641 1879-0097 |
DOI: | 10.1016/j.dental.2019.10.003 |