Macro vitamin B12: an underestimated threat

Background The correct identification of the macro-B12 interference (macroforms) is paramount to avoid potential erroneous clinical decisions. Our objectives were to determine whether immunoassays are affected by the presence of macro-B12 and to validate a polyethylene glycol (PEG) precipitation pro...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical chemistry and laboratory medicine 2020-03, Vol.58 (3), p.408-415
Hauptverfasser: Soleimani, Reza, Favresse, Julien, Roy, Tatiana, Gruson, Damien, Fillée, Catherine
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background The correct identification of the macro-B12 interference (macroforms) is paramount to avoid potential erroneous clinical decisions. Our objectives were to determine whether immunoassays are affected by the presence of macro-B12 and to validate a polyethylene glycol (PEG) precipitation procedure to detect it. Methods Sixty-two serum samples obtained from healthy volunteers were analyzed to determine recovery and reference intervals (RIs) following PEG precipitation. Thereafter, 50 serum samples with very high levels of B12 (>1476 pmol/L) were randomly selected to search for macro-B12 interferences. Serum samples obtained from healthy volunteers and related PEG aliquots were analyzed on a Cobas® immunoassay. Patients' samples were analyzed on both Cobas® and Architect® immunoassays. Finally, samples suspected to contain macro-B12 were analyzed by size-exclusion chromatography (SEC) to confirm the presence of macro-B12. Results Recovery and post-PEG RIs determined on a Cobas 8000® in healthy volunteers ranged from 68.3% to 108.4% and from 122.1 to 514.4 pmol/L, respectively. Fifteen samples (30%) were found to show macro-B12 while using the recovery criteria, and nine samples (18%) while using the post-PEG RI. The other immunoassay ran on the Architect i2000® was also affected by the presence of macro-B12. Size-exclusion chromatography studies confirmed the presence of macro-B12 (immunoglobulin-B12 complexes). Conclusions The prevalence of macro-B12 in elevated B12 samples is high. We suggest to systematically screen for the presence of macro-B12 with PEG precipitation procedure in samples with elevated B12 levels to avoid potential misdiagnosis or harmful clinical consequences.
ISSN:1434-6621
1437-4331
DOI:10.1515/cclm-2019-0999