The effect of foot rotation on measuring ankle alignment using simulated radiographs: a safe zone for pre-operative planning
To assess whether variation in foot rotation, in relation to camera position, affects the reliability of measurement of hindfoot alignment on radiographs and to define a “safe zone” where measurement of the alignment axis and thus preoperative planning is not affected by foot rotation. Healthy volun...
Gespeichert in:
Veröffentlicht in: | Clinical radiology 2019-11, Vol.74 (11), p.897.e1-897.e7 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | To assess whether variation in foot rotation, in relation to camera position, affects the reliability of measurement of hindfoot alignment on radiographs and to define a “safe zone” where measurement of the alignment axis and thus preoperative planning is not affected by foot rotation.
Healthy volunteers were recruited of whom double-sided lower-leg weight-bearing computed tomography (CT) was acquired. Weight-bearing was simulated by means of providing axial compression force equal to the weight of the healthy volunteers. The scans were uploaded into custom-made three-dimensional analysis software to create digitally reconstructed radiographs. For each CT examination, a coordinate system was determined, which defines the neutral position of the leg. Rotation about the z-axis of this coordinate system simulates endo- and exorotation of the foot. Subsequently, radiographs were reconstructed for the leg between 30° of endorotation and 45° of exorotation, and the relation between the observed alignment axis and foot rotation was determined.
A total of 20 healthy volunteers were included, 10 males (mean age 37.7±11.1) and 10 females (mean age 34±10.3). Per 5° of leg rotation, the alignment axis translated with a mean of 6.86% (SD ±13.1). No significant difference in position of the alignment axis was seen between 10° of endorotation and 10° of exorotation compared to the neutral ankle position.
The “safe zone” for imaging the hindfoot alignment axis, is between 10° endo- and 10° exorotation of the foot.
•Foot rotation affects reliability of ankle alignment measurement.•Within the range of 10° endorotation and 10° exorotation of the foot, ankle alignment measurement is not affected by foot rotation.•For coordinate system placement and alignment measurement could be performed with substantial-excellent inter and intra observer reliability. |
---|---|
ISSN: | 0009-9260 1365-229X |