Novel augmented physical simulator for the training of transcatheter cardiovascular interventions

Background Training in transcatheter cardiovascular skills today represents a significant challenge because of the complexity of the interventions and an extensive use of multiple live imaging technologies. Objectives We describe the design, the face validation, and content validation of a newly dev...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Catheterization and cardiovascular interventions 2020-05, Vol.95 (6), p.1202-1209
Hauptverfasser: Zimmermann, Jan M., Steffen, Oliver J., Vicentini, Luca, Schmid Daners, Marianne, Taramasso, Maurizio, Maisano, Francesco, Meboldt, Mirko
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background Training in transcatheter cardiovascular skills today represents a significant challenge because of the complexity of the interventions and an extensive use of multiple live imaging technologies. Objectives We describe the design, the face validation, and content validation of a newly developed physical transseptal puncture (TSP) simulator using additive manufacturing techniques and novel imaging simulation solutions. Methods The TSP simulator contains a femoral vein catheterization pad, silicon phantoms of the venous system, a replaceable interatrial septum, and cameras to mimic live fluoroscopic and echocardiographic imaging. A validation study was conducted at the University Hospital of Zurich. A total of 14 interventional cardiologists and cardiac surgeons assessed the TSP simulator. Participants performed a TSP on the simulator using standard interventional tools. Face and content validity was demonstrated using a 5‐point Likert scale. Results The TSP simulator is a new training tool for transcatheter cardiovascular interventions. All interventional cardiologists and cardiac surgeons completed the training exercise and scoring. Overall impression was rated (out of 5) 4.04 ± 1.03, haptic feedback scored 4.13 ± 0.82, and the realism of fluoroscopy simulation 4.39 ± 0.79. Usability was rated 4.50 ± 0.63 by the participants, indicating that the simulator could be suitable for training. Conclusion We demonstrated face and content validity of a new simulator for transcatheter cardiovascular interventions. The TSP simulator's usability, haptic feedback, imaging solutions, and the overall impression of its usage were reported as very realistic. The TSP simulator represents a promising tool for simulation‐based training using real interventional toolkits in a mimicked radiological environment.
ISSN:1522-1946
1522-726X
DOI:10.1002/ccd.28493