A sensitive quantification approach for detection of HETE-CP adduct after benzyl chloroformate derivatization using ultra-high-pressure liquid chromatography tandem mass spectrometry
Sulfur mustard (HD) reacts with human serum albumin (HSA) at Cys 34 and produces a long-term biomarker of HD exposure. Here, we present a novel, sensitive, and convenient method for quantification of HD exposure by detection of HD-HSA adducts using pronase digestion, benzyl chloroformate (Cbz-Cl) de...
Gespeichert in:
Veröffentlicht in: | Analytical and bioanalytical chemistry 2019-06, Vol.411 (15), p.3405-3415 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Sulfur mustard (HD) reacts with human serum albumin (HSA) at Cys
34
and produces a long-term biomarker of HD exposure. Here, we present a novel, sensitive, and convenient method for quantification of HD exposure by detection of HD-HSA adducts using pronase digestion, benzyl chloroformate (Cbz-Cl) derivatization, and ultra-high-pressure liquid chromatography tandem mass spectrometry (UHPLC-MS/MS). The HSA in HD-exposed plasma in vitro was precipitated with acetone and digested (2 h, 50 °C) with pronase to form the alkylated dipeptide, S-hydroxyethylthioethyl-CysPro (HETE-CP). The HETE-CP adduct was derivatized with Cbz-Cl to generate N-carbobenzoxy HETE-CP (HETE-C(Cbz)P). The derivatized product was analyzed by UHPLC-MS/MS. HD surrogate, 2-chloroethyl ethyl sulfide (2-CEES), was introduced as a non-isotope internal standard (ISTD) instead of traditional
d8
-HD for quantification. The method was found to be linear between 1.00 and 200 ng/mL HD exposure (
R
2
> 0.998) with precision of ≤ 9.0% relative standard deviation (RSD) and accuracy ranged between 97.1 and 111%. The limit of detection (LOD) is 0.500 ng/mL (S/N~5), over 15 times lower than that of the previous method (7.95 ng/mL). Time-consuming affinity purification or solid phase extraction (SPE) is not needed in the experiment and the operation takes less than 5 h. This study provides a new strategy and useful tool for retrospective analysis of HD exposure by HETE-CP biomarker detection.