Evaluation of postoperative sensitivity in restorations with self-adhesive resin: a randomized split-mouth design controlled study
Objectives To evaluate the postoperative sensitivity of restorations with self-adhesive resin composite (SAC) (Vertise Flow (VER)/Kerr) compared with conventional resin composite with self-etching adhesive (Filtek Z250 (Z250)/3M ESPE; Clearfil SE Bond (CSEB)/Kuraray). Materials and methods A randomi...
Gespeichert in:
Veröffentlicht in: | Clinical oral investigations 2020-05, Vol.24 (5), p.1829-1835 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Objectives
To evaluate the postoperative sensitivity of restorations with self-adhesive resin composite (SAC) (Vertise Flow (VER)/Kerr) compared with conventional resin composite with self-etching adhesive (Filtek Z250 (Z250)/3M ESPE; Clearfil SE Bond (CSEB)/Kuraray).
Materials and methods
A randomized, controlled, double-blind, split-mouth, two-arm clinical trial was conducted. Twenty-seven volunteers with third molars indicated for extraction received two deep class I restorations, one with each material. Postoperative sensitivity was measured at 24 h and 15 or 30 days after the restorative procedures using a visual analog scale (VAS). When present, information on the characteristics of the pain was also collected. The data were submitted to the McNemar test (
α
= 0.05).
Results
Regardless of the time intervals, the postoperative sensitivity was observed in 52% and 48% of the CSEB and VERT groups, respectively (
p
= 1.000). When the evaluation periods were analyzed, the 15-day evaluation presented the highest occurrence of pain, but of mild intensity, in both groups. All patients with sensitivity reported that the pain was localized and of short duration.
Conclusion
Self-adhesive resin composite Vertise Flow and conventional resin composite with a self-etching bonding agent promoted similar response regarding postoperative sensitivity in deep class I cavities. When postoperative sensitivity was present, mild pain was observed, especially after 15 days of the restorative procedure, which decreased over time.
Clinical relevance
Postoperative sensitivity to self-adhesive resin composite (SAC) restorations in deep cavities was comparable with that of conventional restorations with a self-etching bonding agent. |
---|---|
ISSN: | 1432-6981 1436-3771 |
DOI: | 10.1007/s00784-019-03046-0 |