Background Large skull base defects can be challenging to repair. This study uses a controlled ex vivo model to examine the failure pressures of various dural repairs of large skull base defects using mucosa with fibrin glue under 3 conditions: No Additional Support of the repair, support with a Fol...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:American journal of rhinology & allergy 2019-11, Vol.33 (6), p.757-762
Hauptverfasser: Chen, Philip G., Clampitt, Michael R., Chorath, Kevin T., Lin, Ryan P., Weitzel, Erik K., McMains, Kevin C., Bunegin, Leonid
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background Large skull base defects can be challenging to repair. This study uses a controlled ex vivo model to examine the failure pressures of various dural repairs of large skull base defects using mucosa with fibrin glue under 3 conditions: No Additional Support of the repair, support with a Foley catheter (Direct Support), and with Foley catheter contact over a rigid acrylic plate (Diffuse Support). Methods Failure pressures of dural repairs with and without support were determined in a porcine model using an ex vivo closed testing apparatus. In addition, 20 mm × 15 mm dural defects were created. Skull base repairs were performed using porcine dura as an underlay graft followed by a septal mucosa overlay. Saline was infused at 30 mL/h, applying even force to the underside of the graft until repair failure occurred for each condition (none, direct, and diffuse support). Five trials were performed per repair type for a total of 15 repairs. Results The mean failure pressures were as follows: No Additional Support, 6.494 ± 2.553 mm Hg; Direct Support, 5.103 ± 3.913 mm Hg; and Diffuse Support, 15.649 ± 2.638 mm Hg. A post hoc Bonferroni-Holm test demonstrated significant difference between No Additional Support and Diffuse Support (P = .001), as well as Direct Support and Diffuse Support (P = .002). Conclusion Support of dural repairs in this model withstood higher pressures when the Foley catheter’s support is distributed evenly using a flat acrylic plate. Use of this plate is the only repair tested in this model that tolerated normal adult supine intracranial pressures.
ISSN:1945-8924
1945-8932
DOI:10.1177/1945892419866310