Accelerating anatomical 2D turbo spin echo imaging of the ankle using compressed sensing
To assess the feasibility and diagnostic value of compressed sensing for accelerating two-dimensional turbo spin echo imaging of the ankle. Ankles of 20 volunteers were scanned (mean age 30.2 ± 7.3 years, 13 men) at 3 T MRI. Coronal and sagittal intermediate-weighted (IM) sequences with fat saturati...
Gespeichert in:
Veröffentlicht in: | European journal of radiology 2019-09, Vol.118, p.277-284 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | To assess the feasibility and diagnostic value of compressed sensing for accelerating two-dimensional turbo spin echo imaging of the ankle.
Ankles of 20 volunteers were scanned (mean age 30.2 ± 7.3 years, 13 men) at 3 T MRI. Coronal and sagittal intermediate-weighted (IM) sequences with fat saturation as well as axial T2- and coronal T1-weighted sequences were acquired using parallel imaging based on sensitivity encoding (SENSE) only as well as with a combination of compressed sensing (CS) and SENSE. Compressed sensing is a technique that acquires less data through k-space random undersampling and enables a reduction in total acquisition time by 20%. All images were reviewed by two radiologists, image quality was graded using a 5-point Likert scale and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of different anatomical structures of the ankle were assessed and compared between sequences with SENSE only and with the combination of CS and SENSE using Wilcoxon signed-rank tests and Cohen’s kappa.
There was a substantial to perfect agreement for the rating between the images acquired with SENSE only and with the combination of CS and SENSE when assessing cartilage, subchondral bone and ligaments (κ = 0.75 - 0.89). SNR was slightly higher for the combination of CS and SENSE sequences compared to the sequences acquired with SENSE only, yet this finding was not significant (P = 0.18-0.62). Moreover, CNR of cartilage/fluid, subchondral bone/cartilage, ligaments/fluid and ligaments/fat did not show significant differences between the sequences acquired with SENSE only and the combination of CS and SENSE (P > 0.05). The interreader agreement was substantial to excellent for both techniques (κ=0.75 - 0.89).
Compressed sensing reduced the acquisition time of conventional MR imaging of the ankle by 20% without decreasing diagnostic image quality, SNR and CNR. |
---|---|
ISSN: | 0720-048X 1872-7727 |
DOI: | 10.1016/j.ejrad.2019.06.006 |