Large head ceramic-on-ceramic bearing in primary total hip arthroplasty: average 3-year follow-up of a multicentre study
Background: Surgeons are increasingly using larger femoral head sizes in total hip arthroplasty (THA) to improve stability and reduce the rate of dislocation, 1 of the leading causes of revision surgery. Large ceramic head sizes up to 48 mm can now be used with monoblock acetabular components. Natio...
Gespeichert in:
Veröffentlicht in: | Hip international 2020-11, Vol.30 (6), p.711-717 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background:
Surgeons are increasingly using larger femoral head sizes in total hip arthroplasty (THA) to improve stability and reduce the rate of dislocation, 1 of the leading causes of revision surgery. Large ceramic head sizes up to 48 mm can now be used with monoblock acetabular components. National registries have shown promising results at short-term with large diameter ceramic-on-ceramic THA, with very low revision rates.
This study reports on the average 3-year follow up of a press-fit monoblock large diameter acetabular shell with a pre-assembled ceramic liner, with emphasis on the radiographic outcome, complications related to the implantation of the cup, and the patient’s clinical outcome.
Methods:
170 hips in 169 patients were reviewed at an average 38 ± 5.8 months following surgery.
Results:
The radiographic review revealed no acetabular cup loosening, no osteolysis and no cup migration. 1 acetabular cup was revised for malposition. The patient clinical outcome and the satisfaction rate were excellent. At 3 years, 7.1% of patients complained of groin pain and 3.5% spontaneously reported hip joint generated noise. 1 patient sustained a non-recurrent traumatic hip dislocation 2 years post surgery.
Conclusions:
New technology should be introduced cautiously on the market. This is especially true for the large diameter ceramic monoblock acetabular component used in this study since it involves a new acetabular component design. At short term, we have not identified new modes of failure with this implant. Longer follow-up is still needed to assess the safety of large ceramic bearing in THA. |
---|---|
ISSN: | 1120-7000 1724-6067 |
DOI: | 10.1177/1120700019863376 |