Head-to-head comparison of plasma cTnI concentration values measured with three high-sensitivity methods in a large Italian population of healthy volunteers and patients admitted to emergency department with acute coronary syndrome: A multi-center study

The study aim is to compare cTnI values measured with three high-sensitivity (hs) methods in apparently healthy volunteers and patients admitted to emergency department (ED) with acute coronary syndrome enrolled in a large multicentre study. Heparinized plasma samples were collected from 1511 appare...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinica chimica acta 2019-09, Vol.496, p.25-34
Hauptverfasser: Clerico, Aldo, Ripoli, Andrea, Zaninotto, Martina, Masotti, Silvia, Musetti, Veronica, Ciaccio, Marcello, Aloe, Rosalia, Rizzardi, Sara, Dittadi, Ruggero, Carrozza, Cinzia, Fasano, Tommaso, Perrone, Marco, de Santis, Antonio, Prontera, Concetta, Riggio, Daniela, Guiotto, Cristina, Migliardi, Marco, Bernardini, Sergio, Plebani, Mario
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The study aim is to compare cTnI values measured with three high-sensitivity (hs) methods in apparently healthy volunteers and patients admitted to emergency department (ED) with acute coronary syndrome enrolled in a large multicentre study. Heparinized plasma samples were collected from 1511 apparently healthy subjects from 8 Italian clinical institutions (mean age: 51.5 years, SD: 14.1 years, range: 18–65 years, F/M ratio:0.95). All volunteers denied chronic or acute diseases and had normal values of routine laboratory tests. Moreover, 1322 heparinized plasma sample were also collected by 9 Italian clinical institutions from patients admitted to ED with clinical symptoms typical of acute coronary syndrome. The reference study laboratory assayed all plasma samples with three hs-methods: Architect hs-cTnI, Access hs-cTnI and ADVIA Centaur XPT methods. Principal Component Analysis (PCA) was also used to analyze the between-method differences among hs-cTnI assays. On average, a between-method difference of 31.2% CV was found among the results of hs-cTnI immunoassays. ADVIA Centaur XPT method measured higher cTnI values than Architect and Access methods. Moreover, 99th percentile URL values depended not only on age and sex of reference population, but also on the statistical approach used for calculation (robust non-parametric vs bootstrap). Due to differences in concentrations and reference values, clinicians should be advised that plasma samples of the same patient should be measured for cTnI assay in the same laboratory. Specific clinical studies are needed to establish the most appropriate statistical approach to calculate the 99th percentile URL values for hs-cTnI methods. •The evaluation of the 99th URL value is a very difficult task that is usually beyond the capacity of a single laboratory.•A multicenter study was promoted in Italy to evaluate and compare reference values of three hs-cTnI methods.•1511 apparently healthy subjects from 8 clinical institutions were enrolled (51.5± 14.1 years, 18-65 years, F/M 0.95).•Due to between-method systematic differences, cTnI measurement should assayed in the same laboratory.•Further studies are needed to establish the appropriate statistical approach to calculate the 99th percentile URL values for hs-cTnI methods.
ISSN:0009-8981
1873-3492
DOI:10.1016/j.cca.2019.06.012