Accuracy of Scanned Stock Abutments Using Different Intraoral Scanners: An In Vitro Study

Purpose To determine the accuracy of a digital manufacturing method for dental implant restorations on stock abutments using intraoral scanners and prefabricated stock‐abutment libraries. Materials and Methods Two dental implants with internal hexagonal connections were placed in the mandibular seco...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of prosthodontics 2019-08, Vol.28 (7), p.797-803
Hauptverfasser: Kim, Jong‐Eun, Hong, Young‐Sun, Kang, You‐Jung, Kim, Jee‐Hwan, Shim, June‐Sung
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose To determine the accuracy of a digital manufacturing method for dental implant restorations on stock abutments using intraoral scanners and prefabricated stock‐abutment libraries. Materials and Methods Two dental implants with internal hexagonal connections were placed in the mandibular second premolar and second molar areas of a partially edentulous dentoform model; stock abutments with a diameter of 5 mm, abutment height of 5.5 mm, and gingival cuff height of 2 mm were connected. The study model was scanned 10 times using a reference tabletop scanner and 5 types of intraoral scanners (IOSs). The data collected by 5 types of IOSs were divided into 3 groups, based on the type and matching of stock abutment library data: no library, optical library, and contact library groups. A total of 160 data files were analyzed, including reference data. The resulting data were used to evaluate trueness and precision. Results Trueness and precision values in the group in which library data of the stock abutment were not used were 42.0 to 76.3 µm and 30.5 to 99.7 µm; corresponding values when the library data using an optical scanner were matched were 51.2 to 73.4 µm and 26.3 to 62.8 µm, and those when contact scanner library data were used were 30.1 to 62.4 µm and 15.5 to 55.9 µm. Thus, the accuracy of the contact library group was significantly higher than the accuracies of the no library (p < 0.001) and optical library groups (p < 0.001). Conclusion The application of prefabricated library data of stock abutments using a contact scanner improved the accuracy of scan data. Scan accuracy of the stock abutments differed significantly based on the type of scanner.
ISSN:1059-941X
1532-849X