Exercise training intensity determination in cardiovascular rehabilitation: Should the guidelines be reconsidered?

Aims In the rehabilitation of cardiovascular disease patients a correct determination of the endurance-type exercise intensity is important to generate health benefits and preserve medical safety. It remains to be assessed whether the guideline-based exercise intensity domains are internally consist...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European journal of preventive cardiology 2019-12, Vol.26 (18), p.1921-1928
Hauptverfasser: Hansen, Dominique, Bonné, Kim, Alders, Toon, Hermans, Ann, Copermans, Katrien, Swinnen, Hans, Maris, Vincent, Jansegers, Thomas, Mathijs, Wout, Haenen, Laura, Vaes, Johan, Govaerts, Emmanuela, Reenaers, Veerle, Frederix, Ines, Dendale, Paul
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Aims In the rehabilitation of cardiovascular disease patients a correct determination of the endurance-type exercise intensity is important to generate health benefits and preserve medical safety. It remains to be assessed whether the guideline-based exercise intensity domains are internally consistent and agree with physiological responses to exercise in cardiovascular disease patients. Methods A total of 272 cardiovascular disease patients without pacemaker executed a maximal cardiopulmonary exercise test on bike (peak respiratory gas exchange ratio >1.09), to assess peak heart rate (HRpeak), oxygen uptake (VO2peak) and cycling power output (Wpeak). The first and second ventilatory threshold (VT1 and VT2, respectively) was determined and extrapolated to %VO2peak, %HRpeak, %heart rate reserve (%HRR) and %Wpeak for comparison with guideline-based exercise intensity domains. Results VT1 was noted at 62 ± 10% VO2peak, 75 ± 10% HRpeak, 42 ± 14% HRR and 47 ± 11% Wpeak, corresponding to the high intensity exercise domain (for %VO2peak and %HRpeak) or low intensity exercise domain (for %Wpeak and %HRR). VT2 was noted at 84 ± 9% VO2peak, 88 ± 8% HRpeak, 74 ± 15% HRR and 76 ± 11% Wpeak, corresponding to the high intensity exercise domain (for %HRR and %Wpeak) or very hard exercise domain (for %HRpeak and %VO2peak). At best (when using %Wpeak) in only 63% and 72% of all patients VT1 and VT2, respectively, corresponded to the same guideline-based exercise intensity domain, but this dropped to about 48% and 52% at worst (when using %HRR and %HRpeak, respectively). In particular, the patient’s VO2peak related to differently elicited guideline-based exercise intensity domains (P 
ISSN:2047-4873
2047-4881
DOI:10.1177/2047487319859450