Biomechanical Evaluation of Mandibular Condyle Fracture Osteosynthesis Using the Rhombic Three-Dimensional Condylar Fracture Plate
The aim of the present study was to evaluate the biomechanical stability of osteosynthesis in mandibular condyle fractures using a newly designed rhombic 3-dimensional (3D) condylar fracture plate and compare it with that using standard two 4-hole miniplates and with that in nonfractured condyles. U...
Gespeichert in:
Veröffentlicht in: | Journal of oral and maxillofacial surgery 2019-09, Vol.77 (9), p.1868.e1-1868.e15 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The aim of the present study was to evaluate the biomechanical stability of osteosynthesis in mandibular condyle fractures using a newly designed rhombic 3-dimensional (3D) condylar fracture plate and compare it with that using standard two 4-hole miniplates and with that in nonfractured condyles.
Using 200 porcine mandibles, 3 different monocortical plating techniques were evaluated. The condyles were fractured along a defined line tangentially through the sigmoid notch and perpendicular to the posterior border. After anatomic reduction, osteosynthesis was performed using either standard rhombic 3D condylar fracture plates and standard screws (group A) or locking rhombic 3D condylar fracture plates, which were fixed either with standard screws (group B) or locking screws (group C). For comparison, nonfractured condyles (group D) and condyles fixed with standard two 4-hole miniplates and 8 screws (group E) were included. Using a universal mechanical testing machine (TIRA Test 2720; TIRA GmbH Schalkau, Germany), each group was subjected to linear loading from laterally to medially, medially to laterally, anteriorly to posteriorly, and posteriorly to anteriorly. The maximum axial force and displacement at the maximum force were measured. The mean values were compared for statistical significance using analysis of variance with Bonferroni's correction (statistical significance set at P |
---|---|