Color change in Perlodel® tablets induced by LED lighting - photolysis of bromocriptine mesylate
Various types of fluorescent lights are found in the dispensing rooms of medical facilities, such as hospitals and pharmacies, in Japan. However, to reduce electric power consumption, it was necessary to evaluate the substitution of fluorescent lighting with light emitting diode (LED) lighting, whic...
Gespeichert in:
Veröffentlicht in: | Pharmazie 2019-05, Vol.74 (5), p.286-289 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Various types of fluorescent lights are found in the dispensing rooms of medical facilities, such as hospitals and pharmacies, in Japan. However, to reduce electric power consumption, it was necessary to evaluate the substitution of fluorescent lighting with light emitting diode (LED)
lighting, which has become widespread in recent years. We subjectively evaluated several types of medicines stored under various light sources and found that different color changes were induced in tablets. In this study, we focused on Perlodel ® tablets, containing 2.5 mg bromocriptine
mesylate, as an example for the objective evaluation of the differences in the color change of tablets when stored under LED lighting and fluorescent lighting. High-performance liquid chromatography (HPLC) analysis of part of the tablet surface area revealed a change from white to light brown
or dark brown after 28 days of irradiation, with a residual concentration of bromocriptine mesylate of 85.5 % under fluorescent lighting, 85.6 % under daylight-color LED lighting, 90.3 % under bulb-color LED lighting, and 99.2 % in the dark. In addition, the ultraviolet (UV)-visible spectral
study of the absorbance of a photo-product at 400-550 nm indicated that the color change of the Perlodel® 2.5 mg tablet was caused by photochemical degradation of bromocriptine mesylate. Thus, this analysis of the photochemical changes in drugs stored under different light
sources demonstrated the potency of LED lights. Through the objective evaluation of the color change, the cause of the color change was determined; this will allow us to develop a strategy that minimizes possible disadvantages to patients, such as a decrease in treatment efficacy owing to
decomposition of the main component or adverse caused by decomposed matter. |
---|---|
ISSN: | 0031-7144 |
DOI: | 10.1691/ph.2019.8109 |