Direct enumeration of coliforms and Escherichia coli by hydrophobic grid membrane filter in 24 hours using MUG

An improved 24-hour grid membrane filter HGMF method for coliform and Escherichia coli enumeration was developed. The new method, which uses a buffered MUG agar for the E. coli portion of the test, was subjected to a pre-collaborative validation study against the 3-tube MPN procedure encompassing 37...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of food protection 1990-11, Vol.53 (11), p.948-952
Hauptverfasser: Entis, P. (QA Laboratories, Toronto, Canada), Boleszczuk, P
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:An improved 24-hour grid membrane filter HGMF method for coliform and Escherichia coli enumeration was developed. The new method, which uses a buffered MUG agar for the E. coli portion of the test, was subjected to a pre-collaborative validation study against the 3-tube MPN procedure encompassing 375 naturally contaminated and inoculated samples representing 25 food products. The HGMF/MUG method produced coliform and E. coli counts equivalent to the conventional method. The confirmation rate of MUG-positive colonies in this study was 98.1%
ISSN:0362-028X
1944-9097
DOI:10.4315/0362-028X-53.11.948