Hemostatic characteristics of thawed, pooled cryoprecipitate stored for 35 days at refrigerated and room temperatures

BACKGROUND Cryoprecipitate's shelf life is limited due to concerns over decreased clotting factor activity and contamination with extended storage. Hemostatic characteristics of thawed cryoprecipitate stored up to 35 days at refrigerated and room temperatures were assessed. STUDY DESIGN AND MET...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Transfusion (Philadelphia, Pa.) Pa.), 2019-04, Vol.59 (S2), p.1560-1567
Hauptverfasser: Fenderson, Joshua L., Meledeo, M. Adam, Rendo, Matthew J., Peltier, Grantham C., McIntosh, Colby S., Davis, Kenneth W., Corley, Jason B., Cap, Andrew P.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:BACKGROUND Cryoprecipitate's shelf life is limited due to concerns over decreased clotting factor activity and contamination with extended storage. Hemostatic characteristics of thawed cryoprecipitate stored up to 35 days at refrigerated and room temperatures were assessed. STUDY DESIGN AND METHODS Pooled cryoprecipitate was thawed and aliquoted for storage at 1–6°C or 21–24°C. Samples were tested immediately after thawing and at 4 h, 24 h, 72 h, and weekly for 35 days. At each time point fibrinogen, factor VIII (FVIII), and von Willebrand factor (vWF) were assessed. Thrombin generation and rotational thromboelastometry (ROTEM) were also performed. Further, packed red cells, platelet concentrates, frozen plasma, and stored cryoprecipitate were combined (1:1:1:1) to simulate massive transfusion and analyzed by ROTEM. Day 35 samples were cultured for bacterial contamination. RESULTS Precipitation was observed in refrigerated samples; however, these aggregates were easily resuspended upon warming in a 37°C water bath. No significant changes were observed in fibrinogen concentration or ROTEM at either temperature. FVIII and vWF declined significantly during storage. vWF, clot time, and thrombin generation were significantly better preserved with refrigeration. With simulated massive transfusion, fibrinogen function remained at or above the established range for whole blood at both storage temperatures. Bacterial contamination was not observed in cold stored or room temperature cryoprecipitate. CONCLUSION The fibrinogen concentration and function of cryoprecipitate at extended storage durations are adequate for fibrinogen replacement in critical bleeding. These results support extension of the shelf life of cryoprecipitate when used for fibrinogen replacement.
ISSN:0041-1132
1537-2995