Pre-Dilatation Versus No Pre-Dilatation for Implantation of a Self-Expanding Valve in All Comers Undergoing TAVR: The DIRECT Trial
The aim of this study was to compare the implantation of a self-expanding valve with or without balloon aortic valvuloplasty (BAV) in an open-label, noninferiority, randomized trial. There are no randomized studies comparing the implantation of a self-expanding valve with (pre-BAV) or without BAV. C...
Gespeichert in:
Veröffentlicht in: | JACC. Cardiovascular interventions 2019-04, Vol.12 (8), p.767-777 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The aim of this study was to compare the implantation of a self-expanding valve with or without balloon aortic valvuloplasty (BAV) in an open-label, noninferiority, randomized trial.
There are no randomized studies comparing the implantation of a self-expanding valve with (pre-BAV) or without BAV.
Consecutive patients with severe aortic stenosis were randomly assigned to undergo transcatheter aortic valve replacement with the use of self-expanding prostheses with (pre-BAV) or without (no-BAV) pre-dilatation. The primary endpoint was device success according to the Valve Academic Research Consortium 2 criteria. Secondary endpoints included periprocedural mortality and stroke, new permanent pacemaker implantation, vascular complications, and 1-year mortality. The trial was scheduled to show noninferiority (Δ = 15%) of the direct versus the pre-BAV approach.
A total of 171 patients were randomized at 4 centers. Of these, 86 underwent transcatheter aortic valve replacement with pre-dilatation and 85 without. Device success was noninferior in the no-BAV group compared with the pre-BAV group (65 of 85 [76.5%] for no-BAV vs. 64 of 86 [74.4%] for pre-BAV; mean difference 2.1%; 90% confidence interval: -8.9% to 13%). In the no-BAV group, 25 patients (29.4%) underwent post-balloon dilatation, and in the pre-BAV group, 13 patients (15.1%) underwent post-balloon dilatation (p = 0.03). Regarding major vascular complications and permanent pacemaker implantation, there was no difference between the 2 groups (log-rank p = 0.49, log-rank p = 0.54). In 1-month completed follow-up for all patients, there was 1 periprocedural stroke (0.5%), without any deaths.
Direct, without balloon pre-dilatation, transcatheter aortic valve replacement with a self-expanding prosthesis system is noninferior to the pre-dilatation procedure. Lower post-dilatation rates were encountered in the group with pre-dilatation. (The Predilatation in Transcatheter Aortic Valve Implantation Trial [DIRECT]; NCT02448927). |
---|---|
ISSN: | 1876-7605 |
DOI: | 10.1016/j.jcin.2019.02.005 |