Goniometric Measurement of Burn Scar Contracture: A Paradigm Shift Challenging the Standard
ABSTRACT Standard goniometry is the most commonly used method of assessing the range of motion (ROM) in patients with burn scar contracture. However, standard goniometry was founded on arthrokinematic principles and doesn’t consider the cutaneous biomechanical influence between adjacent joint positi...
Gespeichert in:
Veröffentlicht in: | Journal of burn care & research 2019-06, Vol.40 (4), p.377-385 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | ABSTRACT
Standard goniometry is the most commonly used method of assessing the range of motion (ROM) in patients with burn scar contracture. However, standard goniometry was founded on arthrokinematic principles and doesn’t consider the cutaneous biomechanical influence between adjacent joint positions and skin pliability to accommodate motion. Therefore, the use of standard goniometry to measure burn scar contracture is called into question. This prospective, multicenter, comparative study investigated the difference between standard goniometry, based on arthrokinematics and a revised goniometry protocol, based on principles of cutaneokinematics and functional positions to measure ROM outcome in burn survivors. Data were collected for 174 joints from 66 subjects at seven burn centers totaling 1044 measurements for comparison. ROM findings using the revised protocol demonstrated significantly more limitation in motion 38.8 ± 15.2% than the standard protocol 32.1 ± 13.4% (p < .0001). Individual analyses of the motions likewise showed significantly more limitation with revised goniometry compared with standard goniometry for 9/11 joint motions. Pearson’s correlation showed a significant positive correlation between the percentage of cutaneous functional units scarred and ROM outcome for the revised protocol (R2 = .05, p = .0008) and the Δ between the revised and standard protocols (R2 = .04, p = .0025) but no correlation was found with the standard goniometric protocol (R2 = .015, p = .065). The results of this study support the hypothesis that standard goniometry underestimates the ROM impairment for individuals whose motion is limited by burn scars. Having measurement methods that consider the unique characteristics of skin impairment and the impact on functional positions is an important priority for both clinical reporting and future research in burn rehabilitation. |
---|---|
ISSN: | 1559-047X 1559-0488 |
DOI: | 10.1093/jbcr/irz038 |