Tikhonov gamma variate adaptive regularization applied to technetium Tc 99m diethylenetriamine pentaacetic acid plasma clearance, compared with three other methods, for measuring glomerular filtration rate in cats
To evaluate agreement of 4 methods (Tikhonov gamma variate adaptive regularization of plasma concentration-time curve fitting applied to technetium Tc 99m diethylenetriamine pentaacetic acid [ Tc-DTPA] plasma clearance [Tk-GV], plasma clearance of exogenous creatinine [CrCL], Gates gamma camera-base...
Gespeichert in:
Veröffentlicht in: | American journal of veterinary research 2019-04, Vol.80 (4), p.416-424 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | To evaluate agreement of 4 methods (Tikhonov gamma variate adaptive regularization of plasma concentration-time curve fitting applied to technetium Tc 99m diethylenetriamine pentaacetic acid [
Tc-DTPA] plasma clearance [Tk-GV], plasma clearance of exogenous creatinine [CrCL], Gates gamma camera-based measurement method with
Tc-DTPA renal clearance and dynamic scintigraphy [GTS], and iohexol renal clearance assessed with dynamic CT with Patlak plotting [CT-Pp]) for measuring glomerular filtration rates (GFR) in healthy cats.
7 healthy, laboratory-raised cats.
Each method for measuring GFR was performed twice in 7 cats at 24-day intervals. The Wilcoxon signed-rank sum test was used to compare the results obtained from the 14 studies for each method. Results from the 4 methods were assessed for agreement and correlation.
The median GFR values were 2.75, 2.83, 3.14, and 4.26 mL/min/kg, for Tk-GV, CT-Pp, plasma CrCL, and GTS, respectively. Analysis with Wilcoxon signed-rank sum tests identified significant pairwise differences between results obtained with the Tk-GV versus the plasma CrCL method, the Tk-GV versus the GTS method, and the plasma CrCL versus the GTS method. The least variable method was Tk-GV, with an SD of 1.27 (mL/min/kg).
Findings indicated that Tk-GV yielded GFR measurements comparable with those obtained with CT-Pp, plasma CrCL, and GTS; however, the Tk-GV method yielded the tightest range of results among the methods evaluated. |
---|---|
ISSN: | 0002-9645 1943-5681 |
DOI: | 10.2460/ajvr.80.4.416 |