Clinical Translation of a Novel Photoacoustic Imaging System for Examining the Temporal Artery

The objective was to provide a clinical setup for photoacoustic imaging (PAI) of the temporal artery in humans and to describe the challenges encountered and methods of overcoming them. The temporal artery was examined in seven patients with suspect giant-cell arteritis (GCA), both in vivo and ex vi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control ferroelectrics, and frequency control, 2019-03, Vol.66 (3), p.472-480
Hauptverfasser: Sheikh, Rafi, Cinthio, Magnus, Dahlstrand, Ulf, Erlov, Tobias, Naumovska, Magdalena, Hammar, Bjorn, Zackrisson, Sophia, Jansson, Tomas, Reistad, Nina, Malmsjo, Malin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The objective was to provide a clinical setup for photoacoustic imaging (PAI) of the temporal artery in humans and to describe the challenges encountered and methods of overcoming them. The temporal artery was examined in seven patients with suspect giant-cell arteritis (GCA), both in vivo and ex vivo , and the results were compared to that of histology. To adapt PAI to the human studies, the transducer was fixed to an adjustable arm to reduce motion artifacts, and a stepping motor was developed to enable 3-D scanning. Risks associated with the use of lasers, ultrasound, and electrical equipment were evaluated by measuring energy levels, and safety precautions were undertaken to prevent injury to the patients and staff. The PAI spectra obtained clearly delineated the artery wall, both in vivo and ex vivo , although the latter was of high quality due to the lack of artifacts. The results could be compared to that of histology. The involved energy levels were found to be below the limits given in regulatory standards. Eye protectors prevented irradiation of the patient's eyes, and visual function after the procedure was found not to be affected. The patients reported no discomfort during the investigations. PAI provides images of the temporal artery wall that may be used for the future diagnosis of GCA in humans. The technique could be further refined by addressing the specific problems of motion artifacts and interference from blood and other chromophores. This study paves the way for other clinical applications of PAI.
ISSN:0885-3010
1525-8955
DOI:10.1109/TUFFC.2018.2868674