Enumeration of indicator organisms in foods using the automated hydrophobic Grid-Membrane Filter technique [Escherichia coli, Staphylococcus aureus]
The automated HGMF technique was compared against accepted traditional methodology for the recovery and enumeration of coliforms, Escherichia coli , enterococci and Staphylococcus aureus from a variety of naturally and artificially contaminated foods. The overall ratios of recovery of the HGMF relat...
Gespeichert in:
Veröffentlicht in: | Journal of food protection 1982-03, Vol.45 (4), p.292-296 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The automated HGMF technique was compared against accepted traditional methodology for the recovery and enumeration of coliforms, Escherichia coli , enterococci and Staphylococcus aureus from a variety of naturally and artificially contaminated foods. The overall ratios of recovery of the HGMF relative to conventional methods were 0.88 for coliforms, 0.80 for E. coli , 0.81 for enterococci and 0.80 for S. aureus . Our results suggest that the automated HGMF system is a viable alternative to conventional most-probable-number and spread plate techniques for the isolation and enumeration of foodborne microorganisms on selective media; however, consideration must be given to modifying procedures for the optimal recovery of stressed cells by this automated membrane filtration technique. |
---|---|
ISSN: | 0362-028X 1944-9097 |
DOI: | 10.4315/0362-028X-45.4.292 |