Enumeration of indicator organisms in foods using the automated hydrophobic Grid-Membrane Filter technique [Escherichia coli, Staphylococcus aureus]

The automated HGMF technique was compared against accepted traditional methodology for the recovery and enumeration of coliforms, Escherichia coli , enterococci and Staphylococcus aureus from a variety of naturally and artificially contaminated foods. The overall ratios of recovery of the HGMF relat...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of food protection 1982-03, Vol.45 (4), p.292-296
Hauptverfasser: Brodsky, M.H, Entis, P, Sharpe, A.N, Jarvis, G.A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The automated HGMF technique was compared against accepted traditional methodology for the recovery and enumeration of coliforms, Escherichia coli , enterococci and Staphylococcus aureus from a variety of naturally and artificially contaminated foods. The overall ratios of recovery of the HGMF relative to conventional methods were 0.88 for coliforms, 0.80 for E. coli , 0.81 for enterococci and 0.80 for S. aureus . Our results suggest that the automated HGMF system is a viable alternative to conventional most-probable-number and spread plate techniques for the isolation and enumeration of foodborne microorganisms on selective media; however, consideration must be given to modifying procedures for the optimal recovery of stressed cells by this automated membrane filtration technique.
ISSN:0362-028X
1944-9097
DOI:10.4315/0362-028X-45.4.292