Brief Report: Real-World Performance and Interobserver Agreement of Urine Lipoarabinomannan in Diagnosing HIV-Associated Tuberculosis in an Emergency Center
BACKGROUND:The urine lipoarabinomannan (LAM) lateral flow assay is a point-of-care test to diagnose HIV-associated tuberculosis (TB). We assessed the performance of urine LAM in HIV-positive patients presenting to the emergency center and evaluated the interobserver agreement between emergency cente...
Gespeichert in:
Veröffentlicht in: | Journal of acquired immune deficiency syndromes (1999) 2019-05, Vol.81 (1), p.e10-e14 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | BACKGROUND:The urine lipoarabinomannan (LAM) lateral flow assay is a point-of-care test to diagnose HIV-associated tuberculosis (TB). We assessed the performance of urine LAM in HIV-positive patients presenting to the emergency center and evaluated the interobserver agreement between emergency center physicians and laboratory technologists.
SETTING:A cross-sectional diagnostic study was performed at the emergency center of a district hospital in a high HIV-prevalence community in South Africa.
METHODS:Consecutive HIV-positive adults presenting with ≥1 WHO TB symptom were enrolled over a 16-month period. A urine LAM test was performed at point-of-care by an emergency physician and interpreted independently by 2 physicians. A second test was performed in the laboratory and interpreted independently by 2 laboratory technologists. The reference standard was a positive TB culture or Xpert MTB/RIF test on sputum or appropriate extrapulmonary samples. We compared diagnostic accuracy and reproducibility of urine LAM between point-of-care readers and laboratory readers.
RESULTS:One thousand three hundred eighty-eight samples (median, 3 samples/participant) were sent for TB microbiology tests in 411 participants; 170 had confirmed TB (41.4%). Point-of-care and laboratory-performed urine LAM had similar sensitivity (41.8% vs 42.0%, P = 1.0) and specificity (90.5% vs 87.5%, P = 0.23). Moderate agreement was found between point-of-care and laboratory testing (κ = 0.62), but there was strong agreement between point-of-care readers (κ = 0.95) and between laboratory readers (κ = 0.94). Positive percent agreement between point-of-care and laboratory readers was 68% and negative percent agreement 92%.
CONCLUSION:There is no diagnostic accuracy advantage in laboratory-performed versus point-of-care–performed urine LAM tests in emergency care centers in high-burden settings. |
---|---|