A metal-organic framework of type MIL-101(Cr) for emulsification-assisted micro-solid-phase extraction prior to UHPLC-MS/MS analysis of polar estrogens
A seamless two-step extraction procedure integrating ultrasound-assisted emulsification microextraction (USAEME) and vortex-assisted micro-solid-phase extraction (μ-SPE) was developed. A highly porous metal-organic framework of type MIL-101(Cr) is used as the sorbent, and ultra-high-performance liqu...
Gespeichert in:
Veröffentlicht in: | Mikrochimica acta (1966) 2019-03, Vol.186 (3), p.165-165, Article 165 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A seamless two-step extraction procedure integrating ultrasound-assisted emulsification microextraction (USAEME) and vortex-assisted micro-solid-phase extraction (μ-SPE) was developed. A highly porous metal-organic framework of type MIL-101(Cr) is used as the sorbent, and ultra-high-performance liquid chromatography in combination with tandem mass spectrometry is used for detection. The steroid hormones estrone 17β-estradiol, estriol, and 17α-ethynylestradiol were extracted from water samples by using this method. These steroids are polar and do not pass through the polypropylene membrane that is conventionally used in μ-SPE. In the method presented here, 1-octanol is used in USAEME to extract and pre-concentrate the steroids. This facilitates the transfer to the MIL-101(Cr) phase retained by the membrane in the subsequent μ-SPE step. MIL-101(Cr) was characterized by various methods, and the parameters affecting the overall extraction efficiency were optimized. Under the most favorable conditions, the limits of detection are between 0.95 and 23 ng L
−1
. Good intra-day and inter-day precisions were obtained, with relative standard deviations of ≤ 9.9%. Enrichment factors are between 34 and 52. The method was applied to genuine environmental water samples in which estrone was detected. Relative recoveries ranged between 85.4% and 120.8%.
Graphical abstract
Schematic of the emulsification-assisted micro-solid-phase extraction (μ-SPE). By emulsifying 1-octanol in the water sample, polar estrogens dissolved in the solvent can easily pass the hydrophobic polypropylene membrane and then are adsorbed onto the unmodified MIL-101(Cr) held within the μ-SPE device. |
---|---|
ISSN: | 0026-3672 1436-5073 |
DOI: | 10.1007/s00604-019-3289-9 |