Whole slide imaging equivalency and efficiency study: experience at a large academic center
Whole slide imaging is Food and Drug Administration-approved for primary diagnosis in the United States of America; however, relatively few pathology departments in the country have fully implemented an enterprise wide digital pathology system enabled for primary diagnosis. Digital pathology has sig...
Gespeichert in:
Veröffentlicht in: | Modern pathology 2019-07, Vol.32 (7), p.916-928 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Whole slide imaging is Food and Drug Administration-approved for primary diagnosis in the United States of America; however, relatively few pathology departments in the country have fully implemented an enterprise wide digital pathology system enabled for primary diagnosis. Digital pathology has significant potential to transform pathology practice with several published studies documenting some level of diagnostic equivalence between digital and conventional systems. However, whole slide imaging also has significant potential to disrupt pathology practice, due to the differences in efficiency of manipulating digital images vis-à-vis glass slides, and studies on the efficiency of actual digital pathology workload are lacking. Our randomized, equivalency and efficiency study aimed to replicate clinical workflow, comparing conventional microscopy to a complete digital pathology signout using whole slide images, evaluating the equivalency and efficiency of glass slide to whole slide image reporting, reflective of true pathology practice workloads in the clinical setting. All glass slides representing an entire day’s routine clinical signout workload for six different anatomic pathology subspecialties at Memorial Sloan Kettering Cancer Center were scanned on Leica Aperio AT2 at ×40 (0.25 µm/pixel). Integration of whole slide images for each accessioned case is through an interface between the Leica eSlide manager database and the laboratory information system, Cerner CoPathPlus. Pathologists utilized a standard institution computer workstation and viewed whole slide images through an internally developed, vendor agnostic whole slide image viewer, named the “MSK Slide Viewer”. Subspecialized pathologists first reported on glass slides from surgical pathology cases using routine clinical workflow. Glass slides were de-identified, scanned, and re-accessioned in the laboratory information system test environment. After a washout period of 13 weeks, pathologists reported the same clinical workload using whole slide image integrated within the laboratory information system. Intraobserver equivalency metrics included top-line diagnosis, margin status, lymphovascular and/or perineural invasion, pathology stage, and the need to order ancillary testing (i.e., recuts, immunohistochemistry). Turnaround time (efficiency) evaluation was defined by the start of each case when opened in the laboratory information system and when the case was completed for that day (i.e., case |
---|---|
ISSN: | 0893-3952 1530-0285 |
DOI: | 10.1038/s41379-019-0205-0 |