Management of Renal Artery Occlusion during Endovascular Aortic Repair
A 67-year-old man was admitted to the emergency unit with abdominal pain. An infrarenal aortic aneurysm with a diameter of 70 millimeters was detected by computed tomography. In the catheter laboratory, graft stents were implanted into the infrarenal aorta. Total occlusion of the right renal artery...
Gespeichert in:
Veröffentlicht in: | Annals of vascular surgery 2019-07, Vol.58, p.380.e9-380.e11 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A 67-year-old man was admitted to the emergency unit with abdominal pain. An infrarenal aortic aneurysm with a diameter of 70 millimeters was detected by computed tomography. In the catheter laboratory, graft stents were implanted into the infrarenal aorta. Total occlusion of the right renal artery was seen in angiography. The graft stent was punctured with a 30° angled Brockenbrough catheter, and another stent was implanted. |
---|---|
ISSN: | 0890-5096 1615-5947 |
DOI: | 10.1016/j.avsg.2018.10.031 |