Evaluation of a Ferromagnetic Marker Technology for Intraoperative Localization of Nonpalpable Breast Lesions

The purpose of this study was to evaluate the magnetic occult lesion localization instrument (MOLLI) system that involves implantation of a small, ferromagnetic marker to guide surgical excision of nonpalpable breast lesions. Characterization of the system was undertaken as part of what is, to our k...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:American journal of roentgenology (1976) 2019-04, Vol.212 (4), p.727-733
Hauptverfasser: Nicolae, Alexandru, Dillon, John, Semple, Mark, Hong, Nicole Look, Ravi, Ananth
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 733
container_issue 4
container_start_page 727
container_title American journal of roentgenology (1976)
container_volume 212
creator Nicolae, Alexandru
Dillon, John
Semple, Mark
Hong, Nicole Look
Ravi, Ananth
description The purpose of this study was to evaluate the magnetic occult lesion localization instrument (MOLLI) system that involves implantation of a small, ferromagnetic marker to guide surgical excision of nonpalpable breast lesions. Characterization of the system was undertaken as part of what is, to our knowledge, the first study to assess the MOLLI system. The MOLLI system consists of a handheld probe that can detect the position and distance of an implanted magnetic marker. The system presents the surgeon with an accurate assessment of lesion location and depth measurement for precise 3D localization. The marker is implanted under ultrasound or mammographic guidance at any time before the surgical procedure and requires no special precautions. Experimental analysis focused on characterization of the following aspects of the MOLLI system: visualization of the marker under imaging, 3D detection of the magnetic marker, spatial resolution of the probe to detect markers placed in close proximity, and the effect of signal interference on system performance. The MOLLI system can reliably detect mean (± SD) marker depths up to 53 ± 8.56 mm from the probe. Bracketing large lesions or localizing multiple lesions can be accomplished by placing markers as close as 10 mm apart, at depths of up to 42 mm. The biologically inert MOLLI marker is readily visible under ultrasound and mammographic guidance, and it is differentiable from radiologic clips. The effect of surgical instruments on MOLLI functioning is minimal and does not impact system accuracy or reliability. The MOLLI system offers an accurate and efficient alternative lesion localization method for nonpalpable breast lesions.
doi_str_mv 10.2214/AJR.18.20195
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2179453831</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2179453831</sourcerecordid><originalsourceid>FETCH-LOGICAL-c291t-42992cc3f47c4f73445f404b8917394e04b27a8c1d599dc599b879f1d06bc1033</originalsourceid><addsrcrecordid>eNo9kDFPwzAQRi0EoqWwMSOPDKT4YieOx1K1UFRAQkViixzHLoEkDnZSqfx6ApQudyd9777hIXQOZByGwK4n989jSMYhAREdoCFELA4oMDhEQ0JjCBJCXwfoxPt3QghPBD9GA0piTimjQ1TNNrLsZFvYGluDJZ5r52wl17VuC4UfpPvQDq-0eqttaddbbKzDi7p10jba9X8bjZdWybL42pc82rqRZSOzUuMbp6Vv8VL7PvSn6MjI0uuz3R6hl_lsNb0Llk-3i-lkGahQQBuwUIhQKWoYV8xwylhkGGFZIoBTwXR_hlwmCvJIiFz1I0u4MJCTOFNAKB2hy7_extnPTvs2rQqvdFnKWtvOpyFwwSKaUOjRqz9UOeu90yZtXFFJt02BpD-C015wCkn6K7jHL3bNXVbpfA__G6Xfvld2hQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2179453831</pqid></control><display><type>article</type><title>Evaluation of a Ferromagnetic Marker Technology for Intraoperative Localization of Nonpalpable Breast Lesions</title><source>American Roentgen Ray Society</source><source>MEDLINE</source><source>Alma/SFX Local Collection</source><creator>Nicolae, Alexandru ; Dillon, John ; Semple, Mark ; Hong, Nicole Look ; Ravi, Ananth</creator><creatorcontrib>Nicolae, Alexandru ; Dillon, John ; Semple, Mark ; Hong, Nicole Look ; Ravi, Ananth</creatorcontrib><description>The purpose of this study was to evaluate the magnetic occult lesion localization instrument (MOLLI) system that involves implantation of a small, ferromagnetic marker to guide surgical excision of nonpalpable breast lesions. Characterization of the system was undertaken as part of what is, to our knowledge, the first study to assess the MOLLI system. The MOLLI system consists of a handheld probe that can detect the position and distance of an implanted magnetic marker. The system presents the surgeon with an accurate assessment of lesion location and depth measurement for precise 3D localization. The marker is implanted under ultrasound or mammographic guidance at any time before the surgical procedure and requires no special precautions. Experimental analysis focused on characterization of the following aspects of the MOLLI system: visualization of the marker under imaging, 3D detection of the magnetic marker, spatial resolution of the probe to detect markers placed in close proximity, and the effect of signal interference on system performance. The MOLLI system can reliably detect mean (± SD) marker depths up to 53 ± 8.56 mm from the probe. Bracketing large lesions or localizing multiple lesions can be accomplished by placing markers as close as 10 mm apart, at depths of up to 42 mm. The biologically inert MOLLI marker is readily visible under ultrasound and mammographic guidance, and it is differentiable from radiologic clips. The effect of surgical instruments on MOLLI functioning is minimal and does not impact system accuracy or reliability. The MOLLI system offers an accurate and efficient alternative lesion localization method for nonpalpable breast lesions.</description><identifier>ISSN: 0361-803X</identifier><identifier>EISSN: 1546-3141</identifier><identifier>DOI: 10.2214/AJR.18.20195</identifier><identifier>PMID: 30673343</identifier><language>eng</language><publisher>United States</publisher><subject>Breast Neoplasms - diagnostic imaging ; Breast Neoplasms - surgery ; Coated Materials, Biocompatible ; Equipment Design ; Female ; Fiducial Markers ; Humans ; Imaging, Three-Dimensional ; Magnetics - instrumentation ; Mammography ; Needles ; Radiography, Interventional ; Surgery, Computer-Assisted - instrumentation ; Ultrasonography, Interventional ; Ultrasonography, Mammary</subject><ispartof>American journal of roentgenology (1976), 2019-04, Vol.212 (4), p.727-733</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c291t-42992cc3f47c4f73445f404b8917394e04b27a8c1d599dc599b879f1d06bc1033</citedby><cites>FETCH-LOGICAL-c291t-42992cc3f47c4f73445f404b8917394e04b27a8c1d599dc599b879f1d06bc1033</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,4110,27915,27916</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30673343$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Nicolae, Alexandru</creatorcontrib><creatorcontrib>Dillon, John</creatorcontrib><creatorcontrib>Semple, Mark</creatorcontrib><creatorcontrib>Hong, Nicole Look</creatorcontrib><creatorcontrib>Ravi, Ananth</creatorcontrib><title>Evaluation of a Ferromagnetic Marker Technology for Intraoperative Localization of Nonpalpable Breast Lesions</title><title>American journal of roentgenology (1976)</title><addtitle>AJR Am J Roentgenol</addtitle><description>The purpose of this study was to evaluate the magnetic occult lesion localization instrument (MOLLI) system that involves implantation of a small, ferromagnetic marker to guide surgical excision of nonpalpable breast lesions. Characterization of the system was undertaken as part of what is, to our knowledge, the first study to assess the MOLLI system. The MOLLI system consists of a handheld probe that can detect the position and distance of an implanted magnetic marker. The system presents the surgeon with an accurate assessment of lesion location and depth measurement for precise 3D localization. The marker is implanted under ultrasound or mammographic guidance at any time before the surgical procedure and requires no special precautions. Experimental analysis focused on characterization of the following aspects of the MOLLI system: visualization of the marker under imaging, 3D detection of the magnetic marker, spatial resolution of the probe to detect markers placed in close proximity, and the effect of signal interference on system performance. The MOLLI system can reliably detect mean (± SD) marker depths up to 53 ± 8.56 mm from the probe. Bracketing large lesions or localizing multiple lesions can be accomplished by placing markers as close as 10 mm apart, at depths of up to 42 mm. The biologically inert MOLLI marker is readily visible under ultrasound and mammographic guidance, and it is differentiable from radiologic clips. The effect of surgical instruments on MOLLI functioning is minimal and does not impact system accuracy or reliability. The MOLLI system offers an accurate and efficient alternative lesion localization method for nonpalpable breast lesions.</description><subject>Breast Neoplasms - diagnostic imaging</subject><subject>Breast Neoplasms - surgery</subject><subject>Coated Materials, Biocompatible</subject><subject>Equipment Design</subject><subject>Female</subject><subject>Fiducial Markers</subject><subject>Humans</subject><subject>Imaging, Three-Dimensional</subject><subject>Magnetics - instrumentation</subject><subject>Mammography</subject><subject>Needles</subject><subject>Radiography, Interventional</subject><subject>Surgery, Computer-Assisted - instrumentation</subject><subject>Ultrasonography, Interventional</subject><subject>Ultrasonography, Mammary</subject><issn>0361-803X</issn><issn>1546-3141</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kDFPwzAQRi0EoqWwMSOPDKT4YieOx1K1UFRAQkViixzHLoEkDnZSqfx6ApQudyd9777hIXQOZByGwK4n989jSMYhAREdoCFELA4oMDhEQ0JjCBJCXwfoxPt3QghPBD9GA0piTimjQ1TNNrLsZFvYGluDJZ5r52wl17VuC4UfpPvQDq-0eqttaddbbKzDi7p10jba9X8bjZdWybL42pc82rqRZSOzUuMbp6Vv8VL7PvSn6MjI0uuz3R6hl_lsNb0Llk-3i-lkGahQQBuwUIhQKWoYV8xwylhkGGFZIoBTwXR_hlwmCvJIiFz1I0u4MJCTOFNAKB2hy7_extnPTvs2rQqvdFnKWtvOpyFwwSKaUOjRqz9UOeu90yZtXFFJt02BpD-C015wCkn6K7jHL3bNXVbpfA__G6Xfvld2hQ</recordid><startdate>201904</startdate><enddate>201904</enddate><creator>Nicolae, Alexandru</creator><creator>Dillon, John</creator><creator>Semple, Mark</creator><creator>Hong, Nicole Look</creator><creator>Ravi, Ananth</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201904</creationdate><title>Evaluation of a Ferromagnetic Marker Technology for Intraoperative Localization of Nonpalpable Breast Lesions</title><author>Nicolae, Alexandru ; Dillon, John ; Semple, Mark ; Hong, Nicole Look ; Ravi, Ananth</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c291t-42992cc3f47c4f73445f404b8917394e04b27a8c1d599dc599b879f1d06bc1033</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Breast Neoplasms - diagnostic imaging</topic><topic>Breast Neoplasms - surgery</topic><topic>Coated Materials, Biocompatible</topic><topic>Equipment Design</topic><topic>Female</topic><topic>Fiducial Markers</topic><topic>Humans</topic><topic>Imaging, Three-Dimensional</topic><topic>Magnetics - instrumentation</topic><topic>Mammography</topic><topic>Needles</topic><topic>Radiography, Interventional</topic><topic>Surgery, Computer-Assisted - instrumentation</topic><topic>Ultrasonography, Interventional</topic><topic>Ultrasonography, Mammary</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Nicolae, Alexandru</creatorcontrib><creatorcontrib>Dillon, John</creatorcontrib><creatorcontrib>Semple, Mark</creatorcontrib><creatorcontrib>Hong, Nicole Look</creatorcontrib><creatorcontrib>Ravi, Ananth</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>American journal of roentgenology (1976)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Nicolae, Alexandru</au><au>Dillon, John</au><au>Semple, Mark</au><au>Hong, Nicole Look</au><au>Ravi, Ananth</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of a Ferromagnetic Marker Technology for Intraoperative Localization of Nonpalpable Breast Lesions</atitle><jtitle>American journal of roentgenology (1976)</jtitle><addtitle>AJR Am J Roentgenol</addtitle><date>2019-04</date><risdate>2019</risdate><volume>212</volume><issue>4</issue><spage>727</spage><epage>733</epage><pages>727-733</pages><issn>0361-803X</issn><eissn>1546-3141</eissn><abstract>The purpose of this study was to evaluate the magnetic occult lesion localization instrument (MOLLI) system that involves implantation of a small, ferromagnetic marker to guide surgical excision of nonpalpable breast lesions. Characterization of the system was undertaken as part of what is, to our knowledge, the first study to assess the MOLLI system. The MOLLI system consists of a handheld probe that can detect the position and distance of an implanted magnetic marker. The system presents the surgeon with an accurate assessment of lesion location and depth measurement for precise 3D localization. The marker is implanted under ultrasound or mammographic guidance at any time before the surgical procedure and requires no special precautions. Experimental analysis focused on characterization of the following aspects of the MOLLI system: visualization of the marker under imaging, 3D detection of the magnetic marker, spatial resolution of the probe to detect markers placed in close proximity, and the effect of signal interference on system performance. The MOLLI system can reliably detect mean (± SD) marker depths up to 53 ± 8.56 mm from the probe. Bracketing large lesions or localizing multiple lesions can be accomplished by placing markers as close as 10 mm apart, at depths of up to 42 mm. The biologically inert MOLLI marker is readily visible under ultrasound and mammographic guidance, and it is differentiable from radiologic clips. The effect of surgical instruments on MOLLI functioning is minimal and does not impact system accuracy or reliability. The MOLLI system offers an accurate and efficient alternative lesion localization method for nonpalpable breast lesions.</abstract><cop>United States</cop><pmid>30673343</pmid><doi>10.2214/AJR.18.20195</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0361-803X
ispartof American journal of roentgenology (1976), 2019-04, Vol.212 (4), p.727-733
issn 0361-803X
1546-3141
language eng
recordid cdi_proquest_miscellaneous_2179453831
source American Roentgen Ray Society; MEDLINE; Alma/SFX Local Collection
subjects Breast Neoplasms - diagnostic imaging
Breast Neoplasms - surgery
Coated Materials, Biocompatible
Equipment Design
Female
Fiducial Markers
Humans
Imaging, Three-Dimensional
Magnetics - instrumentation
Mammography
Needles
Radiography, Interventional
Surgery, Computer-Assisted - instrumentation
Ultrasonography, Interventional
Ultrasonography, Mammary
title Evaluation of a Ferromagnetic Marker Technology for Intraoperative Localization of Nonpalpable Breast Lesions
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T23%3A14%3A56IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20a%20Ferromagnetic%20Marker%20Technology%20for%20Intraoperative%20Localization%20of%20Nonpalpable%20Breast%20Lesions&rft.jtitle=American%20journal%20of%20roentgenology%20(1976)&rft.au=Nicolae,%20Alexandru&rft.date=2019-04&rft.volume=212&rft.issue=4&rft.spage=727&rft.epage=733&rft.pages=727-733&rft.issn=0361-803X&rft.eissn=1546-3141&rft_id=info:doi/10.2214/AJR.18.20195&rft_dat=%3Cproquest_cross%3E2179453831%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2179453831&rft_id=info:pmid/30673343&rfr_iscdi=true