Differences in gross tumor volumes for pancreatic cancer: a comparison of ungated positron emission tomography and contrast-enhanced four-dimensional computed tomography
Purpose We assessed differences in gross tumor volumes (GTVs) for pancreatic cancer between respiratory-ungated positron emission tomography (3D-PET) and contrast-enhanced four-dimensional computed tomography (CE-4DCT). Materials and methods We evaluated the GTVs in 21 patients. The sum of the GTVs,...
Gespeichert in:
Veröffentlicht in: | Japanese journal of radiology 2019-04, Vol.37 (4), p.336-340 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose
We assessed differences in gross tumor volumes (GTVs) for pancreatic cancer between respiratory-ungated positron emission tomography (3D-PET) and contrast-enhanced four-dimensional computed tomography (CE-4DCT).
Materials and methods
We evaluated the GTVs in 21 patients. The sum of the GTVs, which was individually delineated by observers 1 and 2 on the CE-4DCT images from all respiratory phases, was used as GTV-4DCT. The GTVs on the 3D-PET images were extracted with three thresholds: 20%, 30%, and 40% of maximum activity concentration (GTV-
n
%). We selected one of the GTV-
n
%, which mostly resembled GTV-4DCT in size, as GTV-PET. Differences in the GTVs were analyzed.
Results
Median values of GTV-4DCT for observers 1, 2, and GTV-PET were 55.0 mL, 45.7 mL, and 14.6 mL, respectively. GTV-PET was smaller than GTV-4DCT for observers 1 and 2 (
p
|
---|---|
ISSN: | 1867-1071 1867-108X |
DOI: | 10.1007/s11604-019-00812-8 |