Predicting the failure of pulsed magnets

Due to extreme operating conditions, the failure of a magnet frequently occurs in pulsed magnetic field facilities, which not only will disable magnets but also may trigger a violent explosion. Insulation failure occurs more frequently and usually before mechanical failure. Detecting the insulation...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Review of scientific instruments 2018-12, Vol.89 (12), p.124705-124705
Hauptverfasser: Qi, Xin, Xiao, Houxiu, Peng, Tao, Han, Xiaotao, Li, Liang
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Due to extreme operating conditions, the failure of a magnet frequently occurs in pulsed magnetic field facilities, which not only will disable magnets but also may trigger a violent explosion. Insulation failure occurs more frequently and usually before mechanical failure. Detecting the insulation failure of pulsed magnets is an important issue for pulsed high magnetic field systems. The Partial Discharge (PD) signal is usually used as an insulation monitoring tool. However, the weak PD signals are hidden in the strong dB/dt background signals, which are difficult to be separated. This paper will present a differential PD pick-up coil scheme, and the characteristics and mechanism of the PD signals are discussed based on the experimental results.