Absolute quantification (ml blood/sec ∗ mm2 tissue) of normal vs. diabetic foot skin microvascular blood perfusion: Feasibility of FM-PPG measurements under clinical conditions
Fluorescence-mediated photoplethysmography (FM-PPG) is the first routine clinical methodology by which to quantifiably measure tissue blood perfusion in absolute terms (mL blood/sec ∗ mm2 tissue). The FM-PPG methodology has been described in detail previously in this journal (MVR 114, 2017, 92-100),...
Gespeichert in:
Veröffentlicht in: | Microvascular research 2019-05, Vol.123, p.58-61 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Fluorescence-mediated photoplethysmography (FM-PPG) is the first routine clinical methodology by which to quantifiably measure tissue blood perfusion in absolute terms (mL blood/sec ∗ mm2 tissue). The FM-PPG methodology has been described in detail previously in this journal (MVR 114, 2017, 92-100), along with initial proof-of-concept measurements of blood perfusion in both ocular and forearm skin tissues. The motivation for the current study was to investigate whether FM-PPG can be used readily and routinely under realistic clinical conditions. The vehicle for doing this was to measure medial foot capillary blood flow, i.e., tissue perfusion, in 7 normal subjects, mean = 6.76 ± 2.29 E-005 mL/(sec ∙ mm2), and lesion-free areas of 8 type-2 diabetic patients with skin ulceration, mean = 4.67 + 3.15 E-005 mL/(sec ∙ mm2). Thus, perfusion in the diabetics was found to be moderately lower than that in the normal control subjects. Earlier skin perfusion measurements in medial forearms of 4 normal subjects, mean = 2.64 + 0.22 E-005 mL/(sec ∙ mm2), were lower than both the normal and diabetic foot perfusion measurements. Variability in the heartbeat-to-heartbeat blood perfusion pulses in the skin capillaries, defined as the ratio of the standard deviation among beat-to-beat pulses divided by the mean perfusion of those pulses, was determined for each subject. Average variability in foot skin was 21% in the diabetic population, versus 16% for normal subjects; and it was 18% in forearm skin. We conclude that absolute quantitative FM-PPG measurement of skin blood perfusion at the level of nutritive capillaries is feasible routinely under clinical conditions, allowing for quantitative measurement of skin tissue blood perfusion in absolute terms.
•Routine absolute quantification of microvascular blood flow in a clinical setting is obtainable with FM-PPG.•Normal perfusion to the arm appears lower than that in the foot.•Foot perfusion among type-2 diabetics with ulcers was moderately lower than normal. |
---|---|
ISSN: | 0026-2862 1095-9319 |
DOI: | 10.1016/j.mvr.2018.12.004 |