Bivalirudin versus heparin in patients undergoing percutaneous peripheral interventions: A systematic review and meta-analysis
Background Bivalirudin may be an effective alternative anticoagulant to heparin for use in percutaneous peripheral interventions. We aimed to compare the safety and efficacy of bivalirudin versus heparin as the procedural anticoagulant agent in patients undergoing percutaneous peripheral interventio...
Gespeichert in:
Veröffentlicht in: | Vascular 2019-02, Vol.27 (1), p.78-89 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background
Bivalirudin may be an effective alternative anticoagulant to heparin for use in percutaneous peripheral interventions. We aimed to compare the safety and efficacy of bivalirudin versus heparin as the procedural anticoagulant agent in patients undergoing percutaneous peripheral intervention.
Methods
For this meta-analysis and systematic review, we conducted a search in PubMed, Medline, Embase, and Cochrane for all the clinical studies in which bivalirudin was compared to heparin as the procedural anticoagulant in percutaneous peripheral interventions. Outcomes studied included all-cause mortality, all-bleeding, major and minor bleeding, and access site complications.
Results
Eleven studies were included in the analysis, totaling 20,137 patients. There was a significant difference favoring bivalirudin over heparin for all-cause mortality (risk ratio 0.58, 95% CI 0.39–0.87), all-bleeding (risk ratio 0.62, 95% CI 0.50–0.78), major bleeding (risk ratio 0.61, 95% CI 0.39–0.96), minor bleeding (risk ratio 0.66, 95% CI 0.47–0.92), and access site complications (risk ratio 0.66, 95% CI 0.51–0.84). There was no significant difference in peri-procedural need for blood transfusions (risk ratio 0.79, 95% CI 0.57–1.08), myocardial infarction (risk ratio 0.87, 95% CI 0.59–1.28), stroke (risk ratio 0.77, 95% CI 0.59–1.01), intracranial bleeding (risk ratio 0.77, 95% CI 0.29–2.02), or amputations (OR 0.75, 95% CI 0.53–1.05).
Conclusion
Our meta-analysis suggests that bivalirudin use for percutaneous peripheral interventions is associated with lower all-cause mortality, bleeding, and access site complications as compared to heparin. Further large randomized trials are needed to confirm the current results. |
---|---|
ISSN: | 1708-5381 1708-539X |
DOI: | 10.1177/1708538118807522 |