Modeling of pediatric aortic input impedance

Input impedance was calculated from flow and pressure waveforms recorded from the ascending aortas of six pediatric patients ranging in age from 1 to 4 years and weight from 7.2 to 6.4 kg. Impedance curve fits were compared for two four-element lumped parameter models and the three-element modified...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Annals of biomedical engineering 2000-01, Vol.28 (SUPPL. 1), p.S-63
Hauptverfasser: Sharp, MKeith, Pantalos, George M, Minich, LuAnn, Tani, Lloyd Y, McGough, Edwin C
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Input impedance was calculated from flow and pressure waveforms recorded from the ascending aortas of six pediatric patients ranging in age from 1 to 4 years and weight from 7.2 to 6.4 kg. Impedance curve fits were compared for two four-element lumped parameter models and the three-element modified Windkessel model. The results suggested that Rp developed more rapidly with patient weight than did Rc. C increased with increasing patient weight and was 3-16 times lower than adult values.
ISSN:0090-6964