Dose estimation for repeated phosphorus-32 ingestion in human subjects
Dose estimation was conducted for internal phosphorus-32 exposure in one young male subject from repeated oral mis-ingestion for >1 year. Since disclosure for previous continuous contamination, a series of urine samples were collected from this individual weekly for a period of >2 months. P-32...
Gespeichert in:
Veröffentlicht in: | Applied radiation and isotopes 2001-01, Vol.54 (1), p.123-129 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Dose estimation was conducted for internal phosphorus-32 exposure in one young male subject from repeated oral mis-ingestion for >1 year. Since disclosure for previous continuous contamination, a series of urine samples were collected from this individual weekly for a period of >2 months. P-32 radioactivity in urine samples were measured by the acid precipitation method. Estimation for retrospective total effective dose equivalent received by this subject was conducted for cumulative internal dose estimation. A minimum of 9.4 mSv was estimated for an assumed single ingestion. As this was a rare case in radiation protection and internal radiation dosimetry, its implications were of considerable significance. |
---|---|
ISSN: | 0969-8043 1872-9800 |
DOI: | 10.1016/S0969-8043(99)00261-4 |