Charge Displacement by Adhesion and Spreading of a Cell: Amperometric Signals of Living Cells
The amperometric response of single cell adhesion in real time was examined. The technique used is based on measurement of double-layer charge displacement. The flow of compensating current reflects the dynamics of adhesive contact formation and subsequent spreading of a cell. The results demonstrat...
Gespeichert in:
Veröffentlicht in: | Langmuir 2000-10, Vol.16 (21), p.8217-8220 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The amperometric response of single cell adhesion in real time was examined. The technique used is based on measurement of double-layer charge displacement. The flow of compensating current reflects the dynamics of adhesive contact formation and subsequent spreading of a cell. The results demonstrate a general significance of adhesion phenomena in a single particle-electrode interaction. |
---|---|