Improved ultrasound diagnosis of liver metastases with stimulated acoustic emission in the late phase imaging with Levovist
The feasibility of stimulated acoustic emission (SAE) in the liver parenchyma in the late phase imaging with Levovist to improve the ultrasonographical detection of the liver metastases was evaluated. Ten patients with known liver metastases underwent ultrasonography after 5 minutes from the i.v. in...
Gespeichert in:
Veröffentlicht in: | Ultrasound in medicine & biology 2000-01, Vol.26 (SUPPL. 2), p.A155-A155 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The feasibility of stimulated acoustic emission (SAE) in the liver parenchyma in the late phase imaging with Levovist to improve the ultrasonographical detection of the liver metastases was evaluated. Ten patients with known liver metastases underwent ultrasonography after 5 minutes from the i.v. injection of 2,5 g Levovist. The examination was performed in gray-scale with a Siemens Sonoline Elegra equipment, using Contrast Harmonic Imaging and high acoustic power settings. |
---|---|
ISSN: | 0301-5629 |