Wireless Real-Time Temperature Monitoring of Blood Packages: Silver Nanowire-Embedded Flexible Temperature Sensors

Real-time temperature monitoring of individual blood packages capable of wireless data transmission to ensure the safety of blood samples and minimize wastes has become a critical issue in recent years. In this work, we propose flexible temperature sensors using silver nanowires (NWs) and a flexible...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:ACS applied materials & interfaces 2018-12, Vol.10 (51), p.44678-44685
Hauptverfasser: Youn, Doo-Young, Jung, Uihyun, Naqi, Muhammad, Choi, Seon-Jin, Lee, Min-Goo, Lee, Sungho, Park, Hi-Joon, Kim, Il-Doo, Kim, Sunkook
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 44685
container_issue 51
container_start_page 44678
container_title ACS applied materials & interfaces
container_volume 10
creator Youn, Doo-Young
Jung, Uihyun
Naqi, Muhammad
Choi, Seon-Jin
Lee, Min-Goo
Lee, Sungho
Park, Hi-Joon
Kim, Il-Doo
Kim, Sunkook
description Real-time temperature monitoring of individual blood packages capable of wireless data transmission to ensure the safety of blood samples and minimize wastes has become a critical issue in recent years. In this work, we propose flexible temperature sensors using silver nanowires (NWs) and a flexible colorless polyimide (CPI) film integrated with a wireless data transmission circuit. The unique design of the temperature sensors was achieved by patterning Ag NWs using a three-dimensional printed mold and embedding the patterned Ag NWs in the CPI film (p-Ag NWs/CPI), which resulted in a flexible temperature sensor with electrical, mechanical, and temperature stability for applications in blood temperature monitoring. Indeed, a reliable resistance change of the p-Ag NWs/CPI was observed in the temperature range of −20 to 20 °C with a robust bending stability of up to 5000 cycles at 5 mm bending radius. Real-time and wireless temperature monitoring using the p-Ag NWs/CPI was demonstrated with the packages of rat blood. The result revealed that the stable and consistent temperature monitoring of individual blood packages could be achieved in a blood box, which was mainly attributed to the conformal attachment of the p-Ag NWs/CPI to different packages in a blood container.
doi_str_mv 10.1021/acsami.8b11928
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2139583113</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2139583113</sourcerecordid><originalsourceid>FETCH-LOGICAL-a330t-4288d323d7bfc53af6eea071159f8783abc5eb13d1a4ced9a3bb894299d492e23</originalsourceid><addsrcrecordid>eNp1kElLAzEUgIMoLtWrR8lRhKnZpk28aakL1AWteBySyZsSzUxq0nH59460Ch48vXf43gfvQ2ifkj4ljB7rMuna9aWhVDG5hrapEiKTLGfrv7sQW2gnpWdCBpyRfBNtcSKkIoN8G8UnF8FDSvgetM-mrgY8hXoOUS_aCPg6NG4RomtmOFT4zIdg8Z0uX_QM0gl-cP4NIr7RTXjvPNm4NmAtWHzu4cMZ_9f1AE0KMe2ijUr7BHur2UOP5-Pp6DKb3F5cjU4nmeacLDLBpLSccTs0VZlzXQ0ANBlSmqtKDiXXpszBUG6pFiVYpbkxUgmmlBWKAeM9dLj0zmN4bSEtitqlErzXDYQ2FYxylUtOKe_Q_hItY0gpQlXMo6t1_CwoKb47F8vOxapzd3CwcremBvuL_4TtgKMl0B0Wz6GNTffqf7YvDoKJmg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2139583113</pqid></control><display><type>article</type><title>Wireless Real-Time Temperature Monitoring of Blood Packages: Silver Nanowire-Embedded Flexible Temperature Sensors</title><source>ACS Publications</source><creator>Youn, Doo-Young ; Jung, Uihyun ; Naqi, Muhammad ; Choi, Seon-Jin ; Lee, Min-Goo ; Lee, Sungho ; Park, Hi-Joon ; Kim, Il-Doo ; Kim, Sunkook</creator><creatorcontrib>Youn, Doo-Young ; Jung, Uihyun ; Naqi, Muhammad ; Choi, Seon-Jin ; Lee, Min-Goo ; Lee, Sungho ; Park, Hi-Joon ; Kim, Il-Doo ; Kim, Sunkook</creatorcontrib><description>Real-time temperature monitoring of individual blood packages capable of wireless data transmission to ensure the safety of blood samples and minimize wastes has become a critical issue in recent years. In this work, we propose flexible temperature sensors using silver nanowires (NWs) and a flexible colorless polyimide (CPI) film integrated with a wireless data transmission circuit. The unique design of the temperature sensors was achieved by patterning Ag NWs using a three-dimensional printed mold and embedding the patterned Ag NWs in the CPI film (p-Ag NWs/CPI), which resulted in a flexible temperature sensor with electrical, mechanical, and temperature stability for applications in blood temperature monitoring. Indeed, a reliable resistance change of the p-Ag NWs/CPI was observed in the temperature range of −20 to 20 °C with a robust bending stability of up to 5000 cycles at 5 mm bending radius. Real-time and wireless temperature monitoring using the p-Ag NWs/CPI was demonstrated with the packages of rat blood. The result revealed that the stable and consistent temperature monitoring of individual blood packages could be achieved in a blood box, which was mainly attributed to the conformal attachment of the p-Ag NWs/CPI to different packages in a blood container.</description><identifier>ISSN: 1944-8244</identifier><identifier>EISSN: 1944-8252</identifier><identifier>DOI: 10.1021/acsami.8b11928</identifier><identifier>PMID: 30489065</identifier><language>eng</language><publisher>United States: American Chemical Society</publisher><ispartof>ACS applied materials &amp; interfaces, 2018-12, Vol.10 (51), p.44678-44685</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a330t-4288d323d7bfc53af6eea071159f8783abc5eb13d1a4ced9a3bb894299d492e23</citedby><cites>FETCH-LOGICAL-a330t-4288d323d7bfc53af6eea071159f8783abc5eb13d1a4ced9a3bb894299d492e23</cites><orcidid>0000-0002-9970-2218</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://pubs.acs.org/doi/pdf/10.1021/acsami.8b11928$$EPDF$$P50$$Gacs$$H</linktopdf><linktohtml>$$Uhttps://pubs.acs.org/doi/10.1021/acsami.8b11928$$EHTML$$P50$$Gacs$$H</linktohtml><link.rule.ids>314,780,784,2765,27076,27924,27925,56738,56788</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30489065$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Youn, Doo-Young</creatorcontrib><creatorcontrib>Jung, Uihyun</creatorcontrib><creatorcontrib>Naqi, Muhammad</creatorcontrib><creatorcontrib>Choi, Seon-Jin</creatorcontrib><creatorcontrib>Lee, Min-Goo</creatorcontrib><creatorcontrib>Lee, Sungho</creatorcontrib><creatorcontrib>Park, Hi-Joon</creatorcontrib><creatorcontrib>Kim, Il-Doo</creatorcontrib><creatorcontrib>Kim, Sunkook</creatorcontrib><title>Wireless Real-Time Temperature Monitoring of Blood Packages: Silver Nanowire-Embedded Flexible Temperature Sensors</title><title>ACS applied materials &amp; interfaces</title><addtitle>ACS Appl. Mater. Interfaces</addtitle><description>Real-time temperature monitoring of individual blood packages capable of wireless data transmission to ensure the safety of blood samples and minimize wastes has become a critical issue in recent years. In this work, we propose flexible temperature sensors using silver nanowires (NWs) and a flexible colorless polyimide (CPI) film integrated with a wireless data transmission circuit. The unique design of the temperature sensors was achieved by patterning Ag NWs using a three-dimensional printed mold and embedding the patterned Ag NWs in the CPI film (p-Ag NWs/CPI), which resulted in a flexible temperature sensor with electrical, mechanical, and temperature stability for applications in blood temperature monitoring. Indeed, a reliable resistance change of the p-Ag NWs/CPI was observed in the temperature range of −20 to 20 °C with a robust bending stability of up to 5000 cycles at 5 mm bending radius. Real-time and wireless temperature monitoring using the p-Ag NWs/CPI was demonstrated with the packages of rat blood. The result revealed that the stable and consistent temperature monitoring of individual blood packages could be achieved in a blood box, which was mainly attributed to the conformal attachment of the p-Ag NWs/CPI to different packages in a blood container.</description><issn>1944-8244</issn><issn>1944-8252</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNp1kElLAzEUgIMoLtWrR8lRhKnZpk28aakL1AWteBySyZsSzUxq0nH59460Ch48vXf43gfvQ2ifkj4ljB7rMuna9aWhVDG5hrapEiKTLGfrv7sQW2gnpWdCBpyRfBNtcSKkIoN8G8UnF8FDSvgetM-mrgY8hXoOUS_aCPg6NG4RomtmOFT4zIdg8Z0uX_QM0gl-cP4NIr7RTXjvPNm4NmAtWHzu4cMZ_9f1AE0KMe2ijUr7BHur2UOP5-Pp6DKb3F5cjU4nmeacLDLBpLSccTs0VZlzXQ0ANBlSmqtKDiXXpszBUG6pFiVYpbkxUgmmlBWKAeM9dLj0zmN4bSEtitqlErzXDYQ2FYxylUtOKe_Q_hItY0gpQlXMo6t1_CwoKb47F8vOxapzd3CwcremBvuL_4TtgKMl0B0Wz6GNTffqf7YvDoKJmg</recordid><startdate>20181226</startdate><enddate>20181226</enddate><creator>Youn, Doo-Young</creator><creator>Jung, Uihyun</creator><creator>Naqi, Muhammad</creator><creator>Choi, Seon-Jin</creator><creator>Lee, Min-Goo</creator><creator>Lee, Sungho</creator><creator>Park, Hi-Joon</creator><creator>Kim, Il-Doo</creator><creator>Kim, Sunkook</creator><general>American Chemical Society</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-9970-2218</orcidid></search><sort><creationdate>20181226</creationdate><title>Wireless Real-Time Temperature Monitoring of Blood Packages: Silver Nanowire-Embedded Flexible Temperature Sensors</title><author>Youn, Doo-Young ; Jung, Uihyun ; Naqi, Muhammad ; Choi, Seon-Jin ; Lee, Min-Goo ; Lee, Sungho ; Park, Hi-Joon ; Kim, Il-Doo ; Kim, Sunkook</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a330t-4288d323d7bfc53af6eea071159f8783abc5eb13d1a4ced9a3bb894299d492e23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Youn, Doo-Young</creatorcontrib><creatorcontrib>Jung, Uihyun</creatorcontrib><creatorcontrib>Naqi, Muhammad</creatorcontrib><creatorcontrib>Choi, Seon-Jin</creatorcontrib><creatorcontrib>Lee, Min-Goo</creatorcontrib><creatorcontrib>Lee, Sungho</creatorcontrib><creatorcontrib>Park, Hi-Joon</creatorcontrib><creatorcontrib>Kim, Il-Doo</creatorcontrib><creatorcontrib>Kim, Sunkook</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>ACS applied materials &amp; interfaces</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Youn, Doo-Young</au><au>Jung, Uihyun</au><au>Naqi, Muhammad</au><au>Choi, Seon-Jin</au><au>Lee, Min-Goo</au><au>Lee, Sungho</au><au>Park, Hi-Joon</au><au>Kim, Il-Doo</au><au>Kim, Sunkook</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Wireless Real-Time Temperature Monitoring of Blood Packages: Silver Nanowire-Embedded Flexible Temperature Sensors</atitle><jtitle>ACS applied materials &amp; interfaces</jtitle><addtitle>ACS Appl. Mater. Interfaces</addtitle><date>2018-12-26</date><risdate>2018</risdate><volume>10</volume><issue>51</issue><spage>44678</spage><epage>44685</epage><pages>44678-44685</pages><issn>1944-8244</issn><eissn>1944-8252</eissn><abstract>Real-time temperature monitoring of individual blood packages capable of wireless data transmission to ensure the safety of blood samples and minimize wastes has become a critical issue in recent years. In this work, we propose flexible temperature sensors using silver nanowires (NWs) and a flexible colorless polyimide (CPI) film integrated with a wireless data transmission circuit. The unique design of the temperature sensors was achieved by patterning Ag NWs using a three-dimensional printed mold and embedding the patterned Ag NWs in the CPI film (p-Ag NWs/CPI), which resulted in a flexible temperature sensor with electrical, mechanical, and temperature stability for applications in blood temperature monitoring. Indeed, a reliable resistance change of the p-Ag NWs/CPI was observed in the temperature range of −20 to 20 °C with a robust bending stability of up to 5000 cycles at 5 mm bending radius. Real-time and wireless temperature monitoring using the p-Ag NWs/CPI was demonstrated with the packages of rat blood. The result revealed that the stable and consistent temperature monitoring of individual blood packages could be achieved in a blood box, which was mainly attributed to the conformal attachment of the p-Ag NWs/CPI to different packages in a blood container.</abstract><cop>United States</cop><pub>American Chemical Society</pub><pmid>30489065</pmid><doi>10.1021/acsami.8b11928</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0002-9970-2218</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1944-8244
ispartof ACS applied materials & interfaces, 2018-12, Vol.10 (51), p.44678-44685
issn 1944-8244
1944-8252
language eng
recordid cdi_proquest_miscellaneous_2139583113
source ACS Publications
title Wireless Real-Time Temperature Monitoring of Blood Packages: Silver Nanowire-Embedded Flexible Temperature Sensors
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T11%3A57%3A52IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Wireless%20Real-Time%20Temperature%20Monitoring%20of%20Blood%20Packages:%20Silver%20Nanowire-Embedded%20Flexible%20Temperature%20Sensors&rft.jtitle=ACS%20applied%20materials%20&%20interfaces&rft.au=Youn,%20Doo-Young&rft.date=2018-12-26&rft.volume=10&rft.issue=51&rft.spage=44678&rft.epage=44685&rft.pages=44678-44685&rft.issn=1944-8244&rft.eissn=1944-8252&rft_id=info:doi/10.1021/acsami.8b11928&rft_dat=%3Cproquest_cross%3E2139583113%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2139583113&rft_id=info:pmid/30489065&rfr_iscdi=true