Detection of Corrosion in aircraft aluminum alloys

This work shows the application of an aqueous solution of gadolinium nitrate as a contrast agent in samples of AA7075 aluminum alloy used in aircraft structures for neutron radiography (NR) detection of corrosion as the pitting and exfoliation, either hidden or not, by the same alloy. Besides this,...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied radiation and isotopes 1998-07, Vol.49 (7), p.779-782
Hauptverfasser: Crispim, Verginia R., Da Silva, Jesse J.G.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This work shows the application of an aqueous solution of gadolinium nitrate as a contrast agent in samples of AA7075 aluminum alloy used in aircraft structures for neutron radiography (NR) detection of corrosion as the pitting and exfoliation, either hidden or not, by the same alloy. Besides this, inspection for detection of simulated corrosions of several dimensions inside a cylindrical block of aluminum alloy was carried out. The neutron radiographies were taken in the NR device of the external thermal column of the Argonaut reactor, Nuclear Engineering Institute, IEN/CNEN. An image detector was used, consisting of a gadolinium converter, 50 μm thick, and a double-coated Kodak Industrex M film.
ISSN:0969-8043
1872-9800
DOI:10.1016/S0969-8043(97)10006-9