Electrochemical impedance-based DNA sensor using pyrrolidinyl peptide nucleic acids for tuberculosis detection

A label-free electrochemical DNA sensor based on pyrrolidinyl peptide nucleic acid (acpcPNA)-immobilized on a paper-based analytical device (PAD) was developed. Unlike previous PNA-based electrochemical PAD (ePAD) sensors where the capture element was placed directly on the electrode, acpcPNA was co...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytica chimica acta 2018-12, Vol.1044, p.102-109
Hauptverfasser: Teengam, Prinjaporn, Siangproh, Weena, Tuantranont, Adisorn, Vilaivan, Tirayut, Chailapakul, Orawon, Henry, Charles S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A label-free electrochemical DNA sensor based on pyrrolidinyl peptide nucleic acid (acpcPNA)-immobilized on a paper-based analytical device (PAD) was developed. Unlike previous PNA-based electrochemical PAD (ePAD) sensors where the capture element was placed directly on the electrode, acpcPNA was covalently immobilized onto partially oxidized cellulose paper allowing regeneration by simple PAD replacement. As an example application, a sensor probe was designed for Mycobacterium tuberculosis (MTB) detection. The ePAD DNA sensor was used to determine a synthetic 15-base oligonucleotide of MTB by measuring the fractional change in the charge transfer resistance (Rct) obtained from electrochemical impedance spectroscopy (EIS). The Rct of [Fe(CN)6]3-/4- before and after hybridization with the target DNA could be clearly distinguished. Cyclic voltammetry (CV) was used to verify the EIS results, and showed an increase in peak potential splitting in a similar stepwise manner for each immobilization step. Under optimal conditions, a linear calibration curve in the range of 2–200 nM and the limit of detection 1.24 nM were measured. The acpcPNA probe exhibited very high selectivity for complementary oligonucleotides over single-base-mismatch, two-base-mismatch and non-complementary DNA targets due to the conformationally constrained structure of the acpcPNA. Moreover, the ePAD DNA sensor platform was successfully applied to detect PCR-amplified MTB DNA extracted from clinical samples. The proposed paper-based electrochemical DNA sensor has potential to be an alternative device for low-cost, simple, label-free, sensitive and selective DNA sensor. [Display omitted] •An electrochemical paper-based PNA detection method is reported.•The approach uses modified paper as opposed to modified electrodes to enable rapid replacement.•Technique was demonstrated on tuberculosis as a model application.
ISSN:0003-2670
1873-4324
DOI:10.1016/j.aca.2018.07.045