Cannulation of the Femoral Arterial Bypass Cannula Allows Completion of TAVR in Unstable Patients

When hemodynamic instability occurs during transcatheter aortic valve replacement, peripheral cardiopulmonary bypass is required. The pigtail catheter, initially placed through the femoral artery to direct placement of the valve, is exchanged over a wire for an arterial bypass cannula. Other than ti...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Annals of thoracic surgery 2019-04, Vol.107 (4), p.e297-e299
Hauptverfasser: Ajam, Firas, Patel, Swapnil, Asgarian, Koroush, Sealove, Brett, Dejene, Brook, Apolito, Renato, Neibart, Richard M., Carson, Michael P.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:When hemodynamic instability occurs during transcatheter aortic valve replacement, peripheral cardiopulmonary bypass is required. The pigtail catheter, initially placed through the femoral artery to direct placement of the valve, is exchanged over a wire for an arterial bypass cannula. Other than time-consuming arterial cut-down procedures in hypotensive patients, there are few techniques described to allow the operator to continue bypass and complete transcatheter aortic valve replacement. This report describes a method to reintroduce the pigtail catheter by puncturing the arterial bypass cannula. This technique allows the operator to support the patient, continue bypass, and successfully place the valve without aborting the procedure.
ISSN:0003-4975
1552-6259
DOI:10.1016/j.athoracsur.2018.09.072