High-Resolution Extended X‑ray Absorption Fine Structure Analysis Provides Evidence for a Longer Fe···Fe Distance in the Q Intermediate of Methane Monooxygenase

Despite decades of intense research, the core structure of the methane C–H bond breaking diiron­(IV) intermediate, Q, of soluble methane monooxygenase remains controversial, with conflicting reports supporting either a “diamond” diiron core structure or an open core structure. Early extended X-ray a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the American Chemical Society 2018-12, Vol.140 (48), p.16807-16820
Hauptverfasser: Banerjee, Rahul, Zhou, Ang, Que, Lawrence, Lipscomb, John D, DeBeer, Serena
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Despite decades of intense research, the core structure of the methane C–H bond breaking diiron­(IV) intermediate, Q, of soluble methane monooxygenase remains controversial, with conflicting reports supporting either a “diamond” diiron core structure or an open core structure. Early extended X-ray absorption fine structure (EXAFS) data assigned a short 2.46 Å Fe–Fe distance to Q (Shu et al. Science 1997, 275, 515) that is inconsistent with several theoretical studies and in conflict with our recent high-resolution Fe K-edge X-ray absorption spectroscopy (XAS) studies (Castillo et al. J. Am. Chem. Soc. 2017, 139, 18024). Herein, we revisit the EXAFS of Q using high-energy resolution fluorescence-detected extended X-ray absorption fine structure (HERFD-EXAFS) studies. The present data show no evidence for a short Fe–Fe distance, but rather a long 3.4 Å diiron distance, as observed in open core synthetic model complexes. The previously reported 2.46 Å feature plausibly arises from a background metallic iron contribution from the experimental setup, which is eliminated in HERFD-EXAFS due to the increased selectivity. Herein, we explore the origin of the short diiron feature in partial-fluorescent yield EXAFS measurements and discuss the diagnostic features of background metallic scattering contribution to the EXAFS of dilute biological samples. Lastly, differences in sample preparation and resultant sample inhomogeneity in rapid-freeze quenched samples for EXAFS analysis are discussed. The presented approaches have broad implications for EXAFS studies of all dilute iron-containing samples.
ISSN:0002-7863
1520-5126
DOI:10.1021/jacs.8b10313