Measurement of milli-Newton axial force and temperature using a hybrid microsilica sphere Fabry-Perot sensor
An optical fiber sensor based on the Hybrid Fabry-Perot for simultaneous measurement of milli-Newton axial force and temperature is proposed. This structure is composed of a single-mode optical fiber (SMF) integrated to a silica capillary tube (SCT) with polydimethylsiloxane (PDMS). A microsilica sp...
Gespeichert in:
Veröffentlicht in: | Optics letters 2018-11, Vol.43 (21), p.5210-5213 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | An optical fiber sensor based on the Hybrid Fabry-Perot for simultaneous measurement of milli-Newton axial force and temperature is proposed. This structure is composed of a single-mode optical fiber (SMF) integrated to a silica capillary tube (SCT) with polydimethylsiloxane (PDMS). A microsilica sphere cavity (MSSC) is fabricated at the tip of a capillary tube. Consequently, an air gap followed by a microsilica sphere forms two cascade cavities. To explain the transferring load from the SMF to the SCT through PDMS, a shearing mechanism is employed. The experimental results show that axial force and temperature sensitivities of the air gap cavity in the range of 0-3.43 mN and 30-65°C are 170 pm/mN and 24 pm/°C, respectively, while the MSSC did not show any force sensitivity due to its rigidity. However, its temperature sensitivity is 34 pm/°C. The different sensitivities enable us to implement simultaneous sensing of force and temperature. |
---|---|
ISSN: | 0146-9592 1539-4794 |
DOI: | 10.1364/OL.43.005210 |