Performance of membrane-coupled organic acid fermentor for the resources recovery form municipal sewage sludge
This study focused on the treatment performance of membrane-coupled organic acid fermentor (MOF) with intermittent reciprocal air/ozone backwashing for the keeping of high permeation flux as well as for the effective recovery of dissolved organics from municipal sewage sludge. Intermittent reciproca...
Gespeichert in:
Veröffentlicht in: | Water science and technology 2007-01, Vol.55 (10), p.245-252 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This study focused on the treatment performance of membrane-coupled organic acid fermentor (MOF) with intermittent reciprocal air/ozone backwashing for the keeping of high permeation flux as well as for the effective recovery of dissolved organics from municipal sewage sludge. Intermittent reciprocal air/ozone backwashing was effective for membrane fouling reduction. When MOF was operated under the conditions of pH 5.5, hydraulic retention time (HRT) of 2 days and 20 days of solids retention time (SRT), most favourable fermentation efficiency was attained. Great inhibition for acid producing by intermittent reciprocal air/ozone backwashing was not observed during long-term operation. MOF with intermittent reciprocal air/ozone backwashing is believed to be an effective system for the recovery of organic matter from municipal sewage sludge and membrane fouling reduction. |
---|---|
ISSN: | 0273-1223 1996-9732 |
DOI: | 10.2166/wst.2007.328 |