Feasibility of Intraoperative Neuromonitoring During Thyroid Surgery Using Transcartilage Surface Recording Electrodes
Background: Intraoperative neural monitoring (IONM) has gained widespread acceptance as an adjunct to the gold standard of visual identification of the recurrent laryngeal nerve (RLN) during thyroid surgery. Currently, laryngeal electromyography (EMG) recording during IONM is almost always performed...
Gespeichert in:
Veröffentlicht in: | Thyroid (New York, N.Y.) N.Y.), 2018-11, Vol.28 (11), p.158-1516 |
---|---|
Hauptverfasser: | , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background:
Intraoperative neural monitoring (IONM) has gained widespread acceptance as an adjunct to the gold standard of visual identification of the recurrent laryngeal nerve (RLN) during thyroid surgery. Currently, laryngeal electromyography (EMG) recording during IONM is almost always performed using endotracheal tube (ETT) surface electrodes placed adjacent to vocal folds originating from the inner surface of the thyroid cartilage (TC). Therefore, it was hypothesized that surface recording electrodes placed on the outer surface of the TC should enable access to the EMG response of the vocal folds during IONM. The aim of this experimental study was to evaluate the feasibility of the transcartilage approach for laryngeal EMG recording during IONM.
Methods:
A porcine model (12 pigs and 24 RLN sides) with well established applicability in IONM research was used for the experiments. Both ETT electrodes adjacent to vocal folds and adhesive pre-gelled electrodes on the TC were used for EMG recording during IONM. Electrically evoked EMG signals detected by both electrode types were recorded and analyzed. EMG changes during tracheal displacement and RLN traction injury were compared.
Results:
Both the ETT and TC recording electrodes recorded typical laryngeal EMG waveforms evoked by a 1 mA stimulus current applied on both sides of the RLNs and vagus nerves (VNs). Under RLN stimulation, the mean EMG amplitudes recorded with the ETT and TC electrodes were 973 ± 79 μV and 695 ± 150 μV, respectively. Under VN stimulation, the mean amplitudes were 841 ± 163 μV and 607 ± 162 μV, respectively. When upward displacement of the trachea was experimentally induced, the TC electrodes showed less variation in recorded EMG signals compared to ETT electrodes. When RLN traction stress was experimentally induced, both the ETT and TC electrodes accurately recorded the typical EMG pattern of progressively degrading amplitude and gradual recovery after release of traction.
Conclusions:
This study confirms the feasibility of using transcartilage surface electrodes for recording laryngeal EMG signals evoked during IONM in an animal model. However, before practical application of this approach in clinical thyroid surgery, further studies are needed to improve electrode designs by optimizing their shapes and sizes, and increasing their adhesive stability and sensitivity. |
---|---|
ISSN: | 1050-7256 1557-9077 |
DOI: | 10.1089/thy.2017.0680 |