Determination of VX-G Analogue in Red Blood Cells via Gas Chromatography-Tandem Mass Spectrometry Following an Accidental Exposure to VX
A sensitive method for determining exposure to the chemical warfare agent VX is described in which the biomarker ethyl methylphosphonofluoridate (VX-G) is measured in red blood cells (RBCs) following treatment with fluoride ion using isotope-dilution gas chromatography-tandem mass spectrometry. The...
Gespeichert in:
Veröffentlicht in: | Journal of analytical toxicology 2008-01, Vol.32 (1), p.73-77 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A sensitive method for determining exposure to the chemical warfare agent VX is described in which the biomarker ethyl methylphosphonofluoridate (VX-G) is measured in red blood cells (RBCs) following treatment with fluoride ion using isotope-dilution gas chromatography-tandem mass spectrometry. The analyte was isolated via solid-phase extraction and detected using ammonia chemical ionization in the multiple reaction monitoring mode. A good linear relationship was obtained in the quantitative concentration range of 4 ng/mL to 1000 ng/mL with an absolute detection limit of < 1 pg on column. The method has been applied to the analysis of RBCs from a laboratory worker accidentally exposed to VX vapor. Detection and quantitation of VX-G were possible in samples taken as late as 27 days following exposure. |
---|---|
ISSN: | 0146-4760 1945-2403 |
DOI: | 10.1093/jat/32.1.73 |