Off‐label use of duct occluder devices to close hemodynamically significant perimembranous ventricular septal defects: A multicenter experience

Objective We sought to evaluate the feasibility, technical aspects, and outcome of transcatheter perimembranous ventricular septal defect (pmVSD) closure using duct occluder devices with a single retention disc. Background Use of duct occluder devices to close pmVSD seems a promising alternative the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Catheterization and cardiovascular interventions 2019-01, Vol.93 (1), p.82-88
Hauptverfasser: Udink ten Cate, Floris E.A., Sobhy, Rodina, Kalantre, Atul, Sachdev, Sakshi, Subramanian, Anand, Koneti, Nageswara Rao, Kumar, Raman Krishna, Hamza, Hala, Jayranganath, Mahimarangaiah, Sreeram, Narayanswami
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objective We sought to evaluate the feasibility, technical aspects, and outcome of transcatheter perimembranous ventricular septal defect (pmVSD) closure using duct occluder devices with a single retention disc. Background Use of duct occluder devices to close pmVSD seems a promising alternative therapy. However, limited data exist on this technique. Methods From 2010 to 2016, 222 patients (female 47.7%) were identified from databases of five participating institutions in whom pmVSD closure was attempted using an Amplatzer Duct Occluder I or Lifetech duct occluder device. Results Patients ranged in age from 0.7 to 52 years (median, 7.0 years) and in weight from 4.0 to 70 kg (median, 18.0 kg). The mean size of the VSD was 6.8 ± 2.2 mm. A large defect (> 6 mm) was present in 137 patients (61.7%). Device closure was successful in 218 patients (98.2%). The 10/8 mm device was used in most patients (n = 85, 38.3%), and the vascular approach was from the femoral vein in 169 patients (76.1%). There were 18 early complications in 17/218 patients (7.8%). Three patients (1.4%) developed complete heart block (transient n = 2; requiring permanent pacing n = 1). Median follow‐up was 6 months (6 months–6 years). A mild residual shunt was seen in 10 patients at 6 months follow‐up. Conclusions The immediate results of transcatheter pmVSD closure using a duct occluder device with a single retention disc are promising. It is an effective technique with a lower rate of complications than for other currently available devices.
ISSN:1522-1946
1522-726X
DOI:10.1002/ccd.27792