Development of novel portable and reusable fiber optical chemiluminescent biosensor and its application for sensitive detection of microcystin-LR
A novel portable fiber optical chemiluminescent biosensor (FOCB) system was successfully constructed using fiber optic bio-probe as biorecognition element as well as transducer and a Si-based photodiode detector (PD-3000). The compact design of FOCB with free magnetic beads and photomultiplier allow...
Gespeichert in:
Veröffentlicht in: | Biosensors & bioelectronics 2018-12, Vol.121, p.27-33 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A novel portable fiber optical chemiluminescent biosensor (FOCB) system was successfully constructed using fiber optic bio-probe as biorecognition element as well as transducer and a Si-based photodiode detector (PD-3000). The compact design of FOCB with free magnetic beads and photomultiplier allows it to be portable and suitable for on-site and automatic detection of targets, as well as to be cost-effective and small sample volume (only 40.0 µL). The sensitivity of 5 fW could be obtained for the FOCB due to the high performance of PD-3000 and no background light signal. Next, the FOCB was applied for the CL-based detection of microcystin-LR (MC-LR) in water using hapten-carrier protein conjugates modified fiber optic bio-probe as biorecognition element. Based on indirect competitive sandwich-like CL immunoassay principle, the highly sensitive detection of MC-LR was achieved using FOCB system. Under optimal conditions, the limit of detection for MC-LR is 0.03 µg/L, which is comparable with that of most reported MC-LR immunoassay methods. The robustness of the hapten–carrier protein-modified biosensor surface allowed multiple MC-LR immunoassays without any significant loss of performance, which ensured accurate and cost-effective detection results. The proposed strategy demonstrated good recovery, precision, and accuracy through the evaluation of the spiked water samples. The FOCB system can be readily extended toward the on-site real-time sensitive detection of other targets in the field of environment, food, and medical diagnosis.
•Novel FOCB was constructed based on fiber optic bio-probe and photodiode detector.•Portable FOCB can apply for on-site, cost-effective, CL detection of trace targets.•FOCB detected MC-LR using MC-LR-OVA modified bio-probe as biorecognition element.•Sensitive detection of MC-LR was achieved using indirect competitive CL immunoassay.•Biosensor surface allowed multiple MC-LR immunoassays to ensured accurate results. |
---|---|
ISSN: | 0956-5663 1873-4235 |
DOI: | 10.1016/j.bios.2018.08.062 |