Anaerobic filter for polishing effluent of UASB reactor treating strong sewage at 23 deg C

Anaerobic filter (AF) was used for polishing effluent of UASB reactor treating strong sewage at an average water temperature of 23 deg C. The UASB-AF system was operated with sludge discharge taking place only from the AF reactor. It was hypothesized that better removal of suspended COD (CODss) frac...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Water science and technology 2009-01, Vol.59 (10), p.1975-1981
Hauptverfasser: Alrajoula, Mohammad, Halalsheh, Maha, Fayyad, Manar
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Anaerobic filter (AF) was used for polishing effluent of UASB reactor treating strong sewage at an average water temperature of 23 deg C. The UASB-AF system was operated with sludge discharge taking place only from the AF reactor. It was hypothesized that better removal of suspended COD (CODss) fraction from the system can be achieved by increasing sludge discharge frequency from the AF reactor. For this purpose, sludge discharge frequencies of once, twice and thrice per day from the AF reactor were investigated. Results showed that average total COD (CODtot) removal efficiency of the system increased from 62% when sludge was discharged once per day from the AF reactor up to 67% when sludge was discharged twice and thrice per day. However, the increase in CODtot removal was not due to increased removal of CODss fraction; but mainly due to development of an active biomass on the filter media, which increased removal efficiency of soluble COD fraction. The AF reactor had also an evidence of pathogens reduction. The AF reactor achieved 1-2 log reduction in Fecal Coliform counts.
ISSN:0273-1223